FUEL SYSTEM (PGM-FI)
Inspection
Remove the IDC solenoid valve.
Check that the air should flow (A) to (B). only when
the 12 V battery is connected to the IDC solenoid
valve terminals.
CONNECTION:
Battery(+) terminal
Battery(-) terminal - Yellow/black terminal
Check the re sistance between the terminals of the
IDC solenoid valve.
STANDARD: 2s
If the resistance is out of specification, replace the
IDC solenoid valve.
ONE-WAY VALVE
Removal/Installation
Remove the air cleaner housing (page 5-61 ).
Remove the one-way valve by disconnecting the
vacuum hoses.
Installation is in the reverse order of removal.
Route the vacuum
hoses correctly.
Inspection
Check the one-way valve operation as follows:
- Air should flow (A) to (B)
- Air should flow (A) to (C)
- Air should not flow (B) to (A)
- Air should not flow (B) to (C)
If the operation is incorrect, replace the one-way
valve.
5-102
-
Black/white terminal
-
32
n
120 °cIss •FJ
IDC SOLENOID VALVE
Cl