FUEL SYSTEM (PGM-FI)
FUEL CUT-OFF RELAY
INSPECTION
Disconnect the fuel cut-off relay connector (page 5-
54).
Connect the ohmmeter to the fuel cut-off relay con
nector terminals.
CONNECTION: A
Connect the 12 V battery to the following fuel cut-off
relay connector terminals.
CONNECTION: C
There should be continuity only when the 12 V bat
tery is connected. If there is no continuity when the
12 V battery is connected, replace the fuel cut-off
relay.
FUEL TANK
REMOVAL
Relieve the fuel pressure and disconnect the quick
connect fitting from the fuel tank (page 5-51).
Disconnect the fuel level sensor 2P (Natural) con
nector.
Disconnect the fuel tank drain hose and breather
hose from the hose joint.