Fuel Cut-Off Relay; Fuel Tank - Honda CB 600F Hornet 2007 Shop Manual

Table of Contents

Advertisement

FUEL SYSTEM (PGM-FI)

FUEL CUT-OFF RELAY

INSPECTION
Disconnect the fuel cut-off relay connector (page 5-
54).
Connect the ohmmeter to the fuel cut-off relay con­
nector terminals.
CONNECTION: A
Connect the 12 V battery to the following fuel cut-off
relay connector terminals.
CONNECTION: C
There should be continuity only when the 12 V bat­
tery is connected. If there is no continuity when the
12 V battery is connected, replace the fuel cut-off
relay.

FUEL TANK

REMOVAL
Relieve the fuel pressure and disconnect the quick
connect fitting from the fuel tank (page 5-51).
Disconnect the fuel level sensor 2P (Natural) con­
nector.
Disconnect the fuel tank drain hose and breather
hose from the hose joint.
5-58
-
B
-
D
FUEL CUT-OFF RELAY
A
C
\
I,
��
B
D
BREATHER HOSE
BATTERY
DRAIN HOSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents