FUEL SYSTEM (PGM-FI)
Install the fuel tank onto the frame, then install the
pivot bolt and nut.
Hold the pivot bolt and tighten the nut to the speci
fied torque.
TORQUE: 12 N·m (1.2 kgf-m, 9 lbf·ft)
Lift and support the fuel tank (page 3-5).
Connect the fuel tank stopper cable through the
stopper groove of stay.
Install and tighten the nut securely.
Connect the fuel tank drain hose and breather hose
to the hose joint.
NOTICE
• Route the hoses, wires and harness properly
( page 1-23).
• Be careful not to damage the harness and hoses.
• A�er installing the fuel tank, make sure the drain,
breather and fuel hoses are not kinked or bound.
Connect the fuel level sensor 2P (Natural) connec
tor.
Connect the quick connect fitting (page 5-52).
Remove the support tool, then install and tighten
the fuel tank front mounting bolts (page 3-6).
5-60
I
FUEL TANK
BREATHER HOSE
DRAIN HOSE