FUEL SYSTEM (PGM-FI)
Release the IDC solenoid valve vacuum hose from
the ECM.
Release the connectors from the ECM stay.
Disconnect the injector sub-harness 1 OP (Black) and
10P (White) connectors. and 02 sensor 4P (Black)
connector.
Remove the screws and ECM stay.
Pull out the ECM from the air cleaner housing.
Disconnect the ECM 33P (Black and Light gray) con
nectors from the ECM.
Disconnect the CKP sensor 2P (Red) connector.
Release the IDC solenoid valve vacuum hose from
the guide of air cleaner housing.
5-62