Honda CB 600F Hornet 2007 Shop Manual page 185

Table of Contents

Advertisement

Install the IAT sensor with a new O-ring and tighten
the screws securely.
Connect the IAT sensor 2P {Gray) connector.
INSTALLATION
Refer to 'CABLE &
Route the throttle cables to the frame properly, then
HARNESS
install the air cleaner housing with the throttle body
from the left side.
ROUTING' (page 1-
231
NOTICE
Be careful not to damage the harness and hoses.
Make sure each insulator is firmly installed to the
intake port.
Route the starter motor/ground cable to the guide of
air cleaner housing.
Tighten the insulator band screws {cylinder head
side) so that the interval
mm {0.28 ± 0.04 in).
I
of
the band ends is 7
FUEL SYSTEM (PGM-FI)
±
1
7±1mm
(0.28 ±0.04
5-75