To Set the SCSI IDs for the Drives
M
1. At the back of the array, locate the SCSI ID switch (
FIGURE 3-20
Pressing the right switch with a pointed object increments the address. Pressing the
left switch decrements the address.
2. Set the SCSI ID to the number of the base address (first address in the drive
series).
For example, to use SCSI ID addresses 2, 3, and 4 for the first Sun StorEdge S1 array,
set the SCSI toggle switch to 2.
3. If the power is On, cycle it Off then On again.
This step is essential to transfer the updated data to the drives.
4. Repeat Steps 2 and 3 for any additional Sun StorEdge S1 arrays that you may be
installing.
Note – To get the correct SCSI data, the host server must be powered on after any
attached SCSI devices, such as the Sun StorEdge S1 array.
58
Sun StorEdge S1 Array Installation and Maintenance Manual • April 2003
SCSI ID address switches
SCSI ID Switch on the Back of the Array (AC Version)
).
FIGURE 3-20