Precautions on operation control with control terminal(external control)
When Parameter P08 is set to "2", note that the operations are different
due to different settings of P09.
OPEN signal
CLOSE signal
(Terminal No.1)
(Terminal No.2)
OFF
ON
OFF
ON
Note1) When the OPEN / CLOSE signals are turned ON by frequency inverter control:
If Parameter P09 is set to "0, 6", operation status will not change. When the
operation stops and the OPEN / CLOSE signals are turned ON simultaneously,
the operation will not be carried out.
Note2) When the OPEN / CLOSE signals are turned ON by door control:
If Parameter P09 is set to "1, 4", operation status will be ON(forward run) operation.
(OPEN is prior.)
Note3) When the OPEN / CLOSE signals are turned OFF by door control:
If Parameter P09 is set to "1, 4", note that the operations are different due to
different door operation area and different parameter setting status.
Continue to operate(hold operation) in OPEN hold area and CLOSE hold area.
Set parameter d42(stop time of hold operation) if stop operation(hold operation)
is required.
Stop carrying out operation in OPEN operation area and CLOSE operation area.
Set Parameter P70 (forced operation time of fault ON operation) and Parameter
P75(stop select in OPEN/CLOSE operation), if stop operation(hold operation)
is not required.
Note4) Rotation direction setting with door control (repeat):
Start: Start the inverter after rotation direction by OPEN or CLOSE signal is set.
In operation: After the OPEN or CLOSE signal is detected, the rotation direction will
switch automatically. (Arrival hold time may be set by Parameter P72 and P73.)
The rotation direction in "dr mode(rotation direction setting mode) "cannot be set
due to the inconsistence between command signal and control status.
44
0
Frequency
inverter control
Stop
OFF
ON(forward run) operation
OFF
OFF(reverse run) operation
ON
ON
(Note1)
Parameter setting of Parameter P09
6
1
Door control
(normal)
(Note3)
ON(forward run)
operation
(Note2)
4
2
3
Door control (repeat)
Door control (detect)
Stop
Operation (Note 4)
Rotation directions
may switch
automatically.
5