Operatio
Name
Takeout of the
Left Side of a
String
Data Read
from a Given
Position in the
String
Rewrite from a
Given Position
in the String
Replacement
of a Character
String
Character String Conversion Instruction (With Storage Area Size)
Operatio
n
Name
Unit
Conversion:
Character
Constant →
ASCII Code
Text Creation
(With Storage
Area Size)
Date and Time
Character
String
Conversion
(With Storage
Area Size)
String Operation Instruction (With Storage Area Size)
Operatio
n
Name
Unit
String
compare
WUME-FP7CPUPGR-12
n
Mnemonic
Unit
LEFT
(P)
MIDR
(P)
MIDW
(P)
SREP
(P)
Mnemonic
ESSET
(P)
EPRINT
(P)
ETIMEstr (P)
Mnemonic
ESCMP
(P)
1.2 List of High-level Instructions
Operand
Function overview
Retrieves the character strings of [S2]
number of characters from the left side (the
S1, S2,
side where the device address is smaller)
D
of the character string table starting with
[S1], and stores it in [D].
Reads the character strings for [S3]
S1, S2,
number of character strings from the [S2]
byte of the character string table starting
S3, D
with [S1], and stores it in [D].
Reads the character string data for [S2]
S1, S2,
number of characters from the character
string table starting with [S1], and stores it
D, n
in [D] from the position of the [n]th byte.
Replaces the character string table starting
with [D] with the character strings of [S1].
S, D, p, n
The positions and number of characters
that can be replaced are specified with [p]
and [n].
Operand Function overview
Converts the character constant specified
by [S] to ASCII code, and stores it in the
S, D
area starting with [D]. The storage area
size is specified at the head.
Inserts the data to be output [S2] to the text
S1, S2,
creation form [S1], creates the text, and
D
stores it in the area specified by [D]. The
storage area size is specified at the head.
Converts the date and time information
specified by [S1] according to the
S1, S2,
conversion pattern specified by [S2], and
D
stores the character string in the storage
location specified by [D]. The storage area
size is specified at the head.
Operand Function overview
Compares the character string of [S1] with
the character string of [S2], and outputs the
result to the system relay (SRA to SRC).
S1, S2
(S1) > (S2) → SRA:ON
(S1) = (S2) → SRB:ON
(S1) < (S2) → SRC:ON