Fault listing
Fault
Fault name in
code
panel
1
OVERCURRENT
2
DC OVERVOLT
3
DRV OVERTEMP
4
SHORT CIRC
5
OVERLOAD
354
Description and recommended
corrective action
Output current is excessive. Check for and
correct:
• Excessive motor load.
• Insufficient acceleration time (parameters
2202
ACCELER TIME
2).
TIME
• Faulty motor, motor cables or
connections.
Intermediate circuit DC voltage is excessive.
Check for and correct:
• Static or transient over voltages in the
input power supply.
• Insufficient deceleration time (parameters
2203
DECELER TIME
2).
TIME
• Undersized brake chopper (if present).
Drive heatsink is overheated. Temperature
is at or above 115°C (239°F). Check for and
correct:
• Fan failure.
• Obstructions in the air flow.
• Dirt or dust coating on the heat sink.
• Excessive ambient temperature.
• Excessive motor load.
Fault current. Check for and correct:
• A short-circuit in the motor cable(s) or
motor.
• Supply disturbances.
Inverter overload condition. The drive output
current exceeds the ratings given in
"Ratings".