Code
Description
3503
ALARM LIMIT
Defines the alarm limit for motor
temperature measurement.
• At motor temperatures above this limit, the drive displays an
alarm (2010,
For thermistors:
0 = de-activated
1 = activated
3504
FAULT LIMIT
Defines the fault limit for motor temperature measurement.
• At motor temperatures above this limit, the drive displays a
fault (9,
For thermistors:
0 = de-activated
1 = activated
Parameter listing and descriptions
MOTOR OVERTEMP
) and stops the drive.
MOTOR OVERTEMP
Range
-10...200ºC/
0...5000 Ohm
)
0...1
259