Code
Description
1705
OVERRIDE ENABLE
Selects whether the override is enabled or disabled..
0 = OFF - Override disabled.
1 = ON - Override enabled.
• When enabled, the drive stores the values of all
parameters into an override parameter set (see
parameter 9902) and the parameters in Group 17 will be
write protected (except parameter 1704). To change the
other parameters in the Group 17, override has to be
disabled.
216
ACH550 User's Manual
Range
0...1