In general:
No trees (leaves) close to the Charge pole.
The minimal free space at the front of the mast boom is 7.87 Inch.
The total free space at the front of the Charge Pole depending on the bus dimensions.
Height of the pantograph in stand-by mode depends on road- and sideway position,
and position on the mast boom. 181.69 Inch can be used as an average.

3.6. Pole position in relation to the bus

It is important that the pole has the good position in relation with the bus, so that the
pantograph can make physical contact with the charge interface rails on the roof of the bus.
In general the bus has a certain freedom degree to position under the pantograph:
 Z-axis = 23.62 (±11.81) Inch → longitudinal axis;
 Y-axis = 19.69 (±9.84) Inch → transversal axis;
 X-axis = 45.28 Inch → vertical axis;
 When the road is horizontal and the top of road
(TOR) is flat (no wear);
 Compensation of angles: X-axis ≤ 3.5⁰, Z-axis ≤ 2.5⁰.
Before ordering the Charge pole the correct position of the pantograph
within the pole must be calculated by ABB. This is determined during the
site survey for placement of the pole and is performed by ABB. Contact
ABB Sales department (see Contact information on Page 14 for contact
details).
Refer to Page 100 for Pantograph setting range adjustment.