Charge Pole; Description Of User Interface; Charger System Configurations - ABB HVC 150P User Manual

Table of Contents

Advertisement

2.1.2. Charge Pole

A
Door to ACM
B
Emergency button
C
Charge state indicator light (beacon)
D
Distance sensor
E
Pantograph
F
WiFi communication unit
G
RFID unit (if installed, optional)

2.2. Description of user interface

There are three indicator lights (C) at the Charge Pole that serve as an information for the bus
driver:
Color
Under the beacon (C) there is a red Emergency button (B). This Emergency button can be
used only in an emergency situation. When pushing this Emergency button it will immediately
stop the charging process and cut off the DC power from the charger. See also section
Emergency stop on page 16.

2.3. Charger system configurations

The HVC Opportunity Charger is built up with a modular architecture. There are three HVC
Opportunity Charger systems available, depending on the DC output power:
Charger system
HVC 150P Opportunity
Charger
HVC 300P Opportunity
Charger
HVC 450P Opportunity
Charger
Document: v0.4 / Document No.: 6AGA000008-0607-EN | Date: 22-05-2019
State
Continuous
Blinking
Continuous
Blinking
Continuous
Power Cabinet(s)
HVC 150
HVC 150 and HVC 150S
HVC 150 and 2x HVC 150S
Charge status
Ready to charge
Initializing
Charge complete
Charging
Error
DC output power
150 kW
300 kW
450 kW