Rx If Connections; Cdd-562L And Cdd-564L L-Band Chassis Rx Input; Cdd-564 70/140 Mhz Chassis Rx Input - Comtech EF Data CDD-562L Installation And Operation Manual

Demodulator with ip module
Hide thumbs Also See for CDD-562L:
Table of Contents

Advertisement

CDD-562L/564 Demodulator with IP Module
Rear Panel Connections
3.2.1

Rx IF Connections

3.2.1.1

CDD-562L and CDD-564L L-Band Chassis Rx Input

There may be DC voltages present on the Type 'N' Rx IF connectors, up to a
maximum of 48 volts.
The return loss on these ports is typically better than 17 dB, and if the user wishes to connect to a
75Ω system, an inexpensive 'N' to 'F' type adapter can be used and is available as an optional
accessory. While there will be a reduction in return loss when doing this, the effect in most
systems will be imperceptible.
3.2.1.2

CDD-564 70/140 MHz Chassis Rx Input

The Rx IF Input port connectors are BNC female types, with a programmable
impedance of 50Ω or 75Ω. Four connectors, labeled Rx 1 through Rx 4, are provided
on the CDD-564.
The Rx IF input port connectors on the L-Band demodulators are
50Ω 'N' female types. Two connectors, labeled Rx1 and Rx2,
are provided on the CDD-562L (shown at left), while four
connectors labeled Rx A through Rx D are available on the
CDD-564L (shown to the right).
3–3
Revision 2
MN/CDD564L.IOM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdd-564

Table of Contents