Comtech EF Data CDD-562L Installation And Operation Manual page 228

Demodulator with ip module
Hide thumbs Also See for CDD-562L:
Table of Contents

Advertisement

CDD-562L/564 Demodulator with IP Module
Appendix D
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Ping Reply Enabled PRE=
1 byte, value of
0 or 1
Enable/Disable QoS
QSE=
1 byte value
Feature
0 – Disable
1 – Enable
RX Header
RHE=
1 byte, value of
Compression
0, 1, 2 or 3
enable/disable
ReadOnly
ROP=
11 bytes
Password
No spaces
allowed.
ReadOnly
ROU=
11 bytes
UserName
No spaces
allowed.
ReadWrite
RWP=
11 bytes
Password
No spaces
allowed.
ReadWrite
RWU=
11 bytes
UserName
No spaces
allowed.
System
None
String of
Configuration Get
Variable byte
size
SMTP Domain
SDM=
128 bytes,
Name
characters, no
spaces
Query
Command or Query.
Enables or disables ping reply, where:
0 = Disabled
1 = Enabled
Note: When disabled, the modem will not respond to pings (network security feature)
Command or Query.
Sets the Quality of Service feature, where:
0 = Disabled
1 = Enabled
Command or Query.
Enables or disables the Transmit 3xDES feature, where,
0 = Disabled
1 = Enabled
Restriction: Cannot enable if the 3xDES FAST feature has not been purchased
Command or Query.
Changes the ReadOnly password.
Example: ROP =comtech
Command or Query.
Changes the ReadOnly username.
Example: ROU=comtech
Note: To activate the new user name, ROP must be issued immediately after ROU.
Command or Query.
Changes the ReadWrite password.
Example: RWP=comtech
Command or Query.
Changes the ReadWrite username.
Example: RWU=comtech
Note: To activate the new user name, RWP must be issued immediately after RWU.
Query only.
Querying SCG? dumps the system configuration. This can be used for updating the GUI
parameters. See the Appendix section for more information on individual field.
Command or Query.
SMTP Domain name of up to 128 characters.
Note: Entering an empty string will delete the domain name. To delete the domain name,
issue <1/SDM=
Example: SMTP=somedomainname
Description of Arguments
D–12
Revision 2
MN/CDD564L.IOM
Query
Response to
(Instruction
Response to Query
Command
Code and
Qualifier)
PRE =
PRE?
PRE=x
PRE!
(see Description of Arguments)
QSE=
QSE?
QSE=x
QSE!
RHE =
RHE?
RHE =x
RHE!
(see Description of Arguments)
ROP =
ROP?
ROP=xxxxxxxxxxx
ROP!
(see Description of Arguments)
ROU =
ROU?
ROU=xxxxxxxxxx
ROU!
(see Description of Arguments)
RWP =
RWP?
RWP=xxxxxxxxxxx
RWP!
(see Description of Arguments)
RWU =
RWU?
RWU=xxxxxxxxxxx
RWU!
(see Description of Arguments)
SCG=
SCG?
SCG=string of variable byte
SCG!
size.
SDM =
SDM?
SDM=x [1..128]
SDM!
(see Description of Arguments)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDD-562L and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Cdd-564

Table of Contents