Objet500 User Guide
Test Name
Head/Block Heaters
UV Lamps
Axes Limit
Parameter Sanity
Check
Vacuum
DOC-07027 Rev. E
Description
Tests the heaters in the print heads
and in the print-block body.
Tests each UV lamp at the High
Quality power level.
Tests the hardware and software
limits of all axes.
Compares the values of all printer
parameters (in cfg files) to the
required values.
Tests the vacuum level in the print
block.
6 Operating and Maintaining the Objet500 3D Printer
Possible Reason for Failure
Faulty heaters or thermistors.
Faulty UV lamp.
Faulty UV power supply.
Disconnected UV cable.
Faulty hardware sensors.
Wrong Max Position parameter.
One or more of the printer parameters
is not within the required range.
Details appear in the BIT report.
• Faulty vacuum sensor.
• Vacuum leakage.
• Wrong parameters.
6-82