Objet500 User Guide
Calibrating the
Load cells are sensors that measure the weight of the material cartridges and
Load Cells
the waste container in the printer. It is important that you periodically check
that the weight measurements are accurate to prevent unnecessary waste of
printing materials. It is recommended that you calibrate the load cells once a
month.
To calibrate load cells:
1. Start the Load Cell Calibration wizard from the Options menu.
2. In the following screen, select one or more load cells that you want to
3. Remove each selected cartridge from the materials cart, and click Next.
DOC-07027 Rev. E
Figure 6-100 Final UV Calibration Wizard screen
calibrate.
Figure 6-101 Load cell selection
6 Operating and Maintaining the Objet500 3D Printer
6-68