Objet500 User Guide
Warning: Broken UV lamp hazard
UV lamps contain mercury. Deal with broken lamps with caution.
Ventilate the room thoroughly.
l
Use protective gloves when collecting mercury and lamp components.
l
Remove spilled mercury with a method that prevents the generation of
l
mercury vapor, such as a syringe, packing tape or paper.
Place the broken lamp, mercury and contaminated materials in an air-
l
tight, non-metallic container.
10. Insert the new UV lamp/reflector unit into the housing next to the print
11. Replace the UV lamp cover by inserting it into the slot on the bottom of
DOC-07027 Rev. E
block.
Figure 6-111 Print block and UV lamp assembly, showing correct
placement of black strip
the housing, and tighten the securing screw on top.
Figure 6-112 Replacing the UV lamp cover
6 Operating and Maintaining the Objet500 3D Printer
6-73