Objet500 User Guide
Replacing the
The UV lamps used for curing models have a long, but limited, working life.
UV Lamps
You can test and adjust their effective power with the UV Calibration wizard
(see "Testing and Calibrating the UV Lamps" on page 6-61). If you need to
replace a UV lamp, follow these instructions:
1. Make sure the printer is in offline mode.
Warning
Before continuing, make sure that the safety interlock is not defeated, and
that the UV lamp is not hot.
2. Start the UV Lamp Replacement wizard from the Options menu (see
3. Make sure that the build tray is empty, and confirm this in the wizard
DOC-07027 Rev. E
Figure 6-105 Offline mode indicator (red)
The online/offline button at the bottom of the printer interface should be
red. If not, click it to switch the printer to offline mode.
"Cleaning and Replacing the Wiper" on page 6-29).
screen. Then, close the printer cover and click Next.
Figure 6-106 "Empty tray" confirmation screen
The axes move to the "home" position.
6 Operating and Maintaining the Objet500 3D Printer
6-70