Objet500 User Guide
2.  Lead the cable out of the printer so that you can close the printer, and 
3.  Close the printer, while checking that the sensor does not move out of 
4.  Set the UV meter to measure mJ/cm2.
5.  Set the range on the meter to 2,000.
6.  Connect the cable from the sensor to the UV meter. 
7.  Turn on the UV meter, and wait until "0 0 0.0" appears on the display.
8.  In the wizard screen, confirm that the sensor is positioned correctly, and 
Continue with "UV Measurement                 "  below.                
UV Measurement                
The UV lamps power up and stabilize. (This takes several minutes.) Then, the 
print block passes over the sensor and the wizard compares the measured 
radiation to the recommended level for each UV lamp and printing mode. 
During this process, which takes 20–40 minutes, you need to monitor the 
progress as displayed in the wizard screen.
DOC-07027 Rev. E
tape it down to make sure that it does not interfere with the moving print 
block.
Tape the cable to the build tray to keep it in place.
Figure 6-96    Correct UV-sensor placement
position.
click Next.
6 Operating and Maintaining the Objet500 3D Printer
 
6-66