Objet500 User Guide
Optimizing
The condition of the print heads directly affects the quality of printed models.
(Calibrating)
To maintain optimum printing, you should routinely test the print heads, and
Print Heads
calibrate them to the best working configuration possible by running the
Head Optimization wizard every 300 hours of printing.
During this procedure, you place a scale on the build tray and connect it to
the printer. Printing material (resin) is jetted from each head and its weight is
automatically recorded and the wizard determines how to optimize the print
heads.
If, during the optimization process, the wizard determines that a print head is
faulty—or that it is negatively affecting layer uniformity with the current head
configuration—the wizard instructs you to replace it. If this happens, you can
continue the wizard to replace the print head, or abort the wizard, to replace
the head at another time.
Run the Head Optimization wizard whenever the condition of print heads
is negatively affecting the quality of printed models, or if you suspect that
there is a problem with one or more of the print heads.
Note: Allow at least 40-50 minutes per mode f or performing this procedure
(not including time required for replacing faulty print heads). To accurately
test and calibrate print heads, they must be clean. If necessary, run the Head
Cleaning wizard before beginning this procedure.
To test and calibrate the print heads:
1. Prepare—
2. Check that there is a material cartridge loaded in the M3 slot. If necessary,
DOC-07027 Rev. E
❒ disposable cleaning gloves (any clean, powder-free protective gloves)
❒ pink paper
❒ the Missing Nozzles ruler
❒ the scale supplied for use in the Head Optimization wizard
Important: Ensure that the scale is calibrated and charged before
beginning this procedure. It is highly recommended to connect the scale
to the wall power socket when running this wizard.
insert a cartridge that contains different material than is loaded in the
other slotscartridge.
Note: The Head Optimization wizard will not operate if the M3 cartridge
slot is empty.
6 Operating and Maintaining the Objet500 3D Printer
6-43