Stratasys Objet500 User Manual page 168

Hide thumbs Also See for Objet500:
Table of Contents

Advertisement

Objet500 User Guide
2.  Loosen the screws securing the suction tube.
3.  Lower the suction tube so that the hole in the panel behind the tube is 
4.  Attach the right-UV-lamp assembly to the print block and reconnect the 
You should replace the roller scraper blade—
Replacing the
Roller Scraper
• after 1,000 hours of printing.
• if it does not effectively keep the roller clean.
You should periodically test the effectiveness of the roller scraper when 
you clean the roller waste collector. See "Cleaning the Roller Waste 
Collector and Inspecting the Roller Scraper" on page 6-34.
To replace the roller scraper:
1.  Prepare—
2.  Remove the right UV lamp and the roller waste collector covering (see 
3.  Loosen the two screws securing the roller waste collector and pull it out.
DOC-07027 Rev. E
Figure 6-41    Suction tube correctly positioned
visible, and tighten the screws to secure the tube. 
UV power and fan cables.
❒  a new roller scraper blade (KIT-01026-S)
❒  a Phillips 1x75 mm screwdriver
❒  M2.5 and M2 Hex (Allen) keys
steps 3 to 6  on page 6-34).
Figure 6-42    Removing the roller waste collector
6 Operating and Maintaining the Objet500 3D Printer
6-37

Advertisement

Table of Contents
loading