Endress+Hauser Levelflex FMP51 Operating Instructions Manual page 147

Guided level-radar
Hide thumbs Also See for Levelflex FMP51:
Table of Contents

Advertisement

Levelflex FMP51, FMP52, FMP54
Description
Options
Factory setting
Assign limit
Navigation
Prerequisite
Description
Options
Factory setting
Assign diagnostic level
Navigation
Prerequisite
Description
Options
Factory setting
Endress+Hauser
Allocates a DI block to the switch output.
• Off
No digital block is allocated.
• Digital output 1
• Digital output 2
• Digital output 3
• Digital output 4
Off
Setup ® Advanced setup ® Switch output ® Assign limit
Only visible for Switch output function = Limit.
Defines the variable to be checked for limit transgression and allocates it to the switch output.
• Off
No measured variable is allocated.
• Level linearized
• Distance
• Interface linearized
• Interface distance
• Upper interface thickness
• Terminal voltage
• Electronic temperature
• Relative echo amplitude
• Relative interface amplitude
Off
Setup ® Advanced setup ® Switch output ® Assign diagnostic level
Only visible for Switch output function = Event level.
Defines to which class of diagnostic events the output reacts.
• Alarm
• Alarm + warning
• Warning
Alarm
Description of device parameters (operating menu)
147

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Levelflex FMP51 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Levelflex fmp52Levelflex fmp53

Table of Contents

Save PDF