Description of device parameters (operating menu)
Use calculated DC
Navigation
Meaning
Selection
Factory setting
Additional information
136
Setup ® Advanced setup ® Interface ® Autom. DC calc. ® Use calc. DC
Confirm if the automatically calclualted DC is to be used.
• Save and exit
The calculated DC is accepted. The device quits the sequence ("End of sequence" is displayed).
• Cancel and exit
The calculated DC is rejected; the device continues to use the old DC and quits the sequence
("End of sequence" is displayed).
• Re-input thickness
The calculated DC is rejected. The device returns to the Manual interface thickness
parameter, so that a corrected value of the manual interface thickness can be entered.
Cancel and exit
The calculated DC is indicated on the display together with this parameter.
Levelflex FMP51, FMP52, FMP54