Description of device parameters (operating menu)
Description
Selection
Factory setting
Additional information
Free text
Navigation
Condition
Description
Input range
Factory setting
Maximum value
Navigation
Condition
Description
Input range
138
Defines the unit of the linearized value.
• Free text
• t
• lb
• ton
• kg
• impGal
• UsGal
• cf
• cm
3
• dm
3
3
• m
• hl
• l
• %
%
The selected unit is only used to be indicated on the display. The measured value is not
transformed according to the selected unit.
Setup ® Advanced setup ® Linearization ® Free text
Only visible for Unit lienarized = Free text.
Definiton of the unit
Up to 32 alphanumerical characters (letters, numbers, special characters)
Free text
Setup ® Advanced setup ® Linearization ® Maximum value
Only visible if one of the following linearization types has been selected:
• Linear
• Pyramid bottom
• Conical bottom
• Angled bottom
• Horizontal cylinder
• Sphere
Definition of the maximum content of the vessel (100%), as measured in the Unit linearized.
-50000 ... +50000
Levelflex FMP51, FMP52, FMP54
Endress+Hauser
Need help?
Do you have a question about the Levelflex FMP51 and is the answer not in the manual?
Questions and answers