Description of device parameters (operating menu)
Additional information
Level correction
Navigation
Description
Input range
Factory setting
Additional information
134
Echoes from within the blocking distance are not
taken into account in the signal evaluation. The
upper blocking distance is used
• to suppress interference echoes at the top end of
the probe (1).
• to suppress the echo of the total level in the case
of flooded bypasses (2).
Setup ® Advanced setup ® Interface ® Level correction
Defines the level correction
Depending on the selected level unit:
• -100,0 ... 100,0 %
• -200,0 ... +200,0 m
• -656,2 ... +656,2 ft
• -7874,0 ... +7874,0 inch
• -200.000,0 ... +200.000,0 mm
0%
The value specified in this parameter is added to the measured total and interface level.
Levelflex FMP51, FMP52, FMP54
1
UB
Endress+Hauser
2
UB
A0013220