Technical data
Model number
Interfaces
POWERLINK
Quantity
Type
Variant
Transfer rate
Transfer
Cable length
Electrical properties
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Ambient conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical properties
Weight
1)
For additional information, see Automation Help (Communication - POWERLINK - General - Hardware - IF / LS).
2)
For detailed information, see the temperature tables in the user's manual.
4.7.4.12.3.1 POWERLINK 1 interface - Pinout
The POWERLINK 1 interface is available in the IF option 2 slot.
Variant
Wiring
Cable length
LED "Link" (a)
Orange (light)
LED "Status" (b)
Green/Red
1)
The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the
numbering used by the respective operating system, however.
4.7.4.12.3.2 POWERLINK 2 interface - Pinout
The POWERLINK 2 interface is available in the IF option 2 add-on slot.
Variant
Wiring
Cable length
LED "Link" (a)
Orange (light)
LED "Status" (b)
Green/Red
1)
The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the
numbering used by the respective operating system, however.
4.7.4.12.3.3 POWERLINK commissioning and operation
For a description of the operating modes, status and node numbers of the POWERLINK interface(s), see
"LED "S/E" (LED "Status/Error")" on page
4.7.4.12.4 Driver support and firmware update
The driver is part of the Automation Runtime and the firmware is part of Automation Studio. The module is auto-
matically brought up to this level.
88
POWERLINK 1 - IF1
RJ45, female
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
Link (a connection to a POW-
ERLINK network exists)
On
POWERLINK status
see "LED "S/E" (LED "Status/Error")" on page 242
POWERLINK 2 - IF2
RJ45, female
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
Link (a connection to a POW-
ERLINK network exists)
On
POWERLINK status
see "LED "S/E" (LED "Status/Error")" on page 242
242.
5ACCIF02.FPLK-000
1 (integrated 2-port hub)
Type 4, redundant
RJ45, shielded
100 Mbit/s
100BASE-TX
Max. 100 m between two stations (segment length)
2 W
Pollution degree 2
0 to 55°C
2)
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
Approx. 100 g
1)
Active
Blinking (data be-
ing transferred)
Off
1)
Active
Blinking (data be-
ing transferred)
Off