B&R Automation PC 810 User Manual
B&R Automation PC 810 User Manual

B&R Automation PC 810 User Manual

With gm45 cpu board
Hide thumbs Also See for Automation PC 810:
Table of Contents

Advertisement

Quick Links

Automation PC 810
with GM45 CPU Board
User's Manual
Version: 1.38 (March 2015)
Model no.: MAAPC800A-ENG
All information contained in this manual is current as of its creation/publication. B&R reserves the right to change
the contents of this manual without notice. The information contained herein is believed to be accurate as of
the date of publication; however, Bernecker + Rainer Industrie-Elektronik Ges.m.b.H. makes no warranty, ex-
pressed or implied, with regard to the products or documentation contained within this manual. In addition,
Bernecker + Rainer Industrie-Elektronik Ges.m.b.H. shall not be liable for any incidental or consequential damages
in connection with or arising from the furnishing, performance or use of the product(s) in this documentation. Soft-
ware names, hardware names and trademarks are registered by their respective companies.
1

Advertisement

Table of Contents
loading

Summary of Contents for B&R Automation PC 810

  • Page 1 Automation PC 810 with GM45 CPU Board User's Manual Version: 1.38 (March 2015) Model no.: MAAPC800A-ENG All information contained in this manual is current as of its creation/publication. B&R reserves the right to change the contents of this manual without notice. The information contained herein is believed to be accurate as of the date of publication;...
  • Page 2 Chapter 1: General information Chapter 2: Technical data Chapter 3: Installation Chapter 4: Software Chapter 5: Standards and certifications Chapter 6: Accessories Chapter 7: Maintenance and service Appendix A...
  • Page 3: Table Of Contents

    2.6.1 +24 VDC power supply.........................49 2.6.2 COM1 serial interface........................... 50 2.6.3 COM2 serial interface........................... 50 2.6.4 Monitor/Panel interface - SDL (Smart Display Link / DVI)..............51 2.6.5 Ethernet 1 (ETH1)..........................53 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 4 3.6.8 5AC801.SSDI-03..........................117 3.6.9 5AC801.SSDI-04..........................120 3.6.10 5AC801.SSDI-05..........................123 3.6.11 5AC801.ADAS-00..........................125 3.6.12 5AC801.HDDS-00..........................126 3.6.13 5AC801.DVDS-00..........................128 3.6.14 5AC801.DVRS-00..........................130 3.6.15 5ACPCI.RAIC-03..........................133 3.6.16 5ACPCI.RAIC-04..........................136 3.6.17 5ACPCI.RAIC-05..........................138 3.6.18 5ACPCI.RAIC-06..........................141 3.6.19 5MMHDD.0250-00..........................144 3.6.20 5MMHDD.0500-00..........................146 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 5 5.3.2 Link modules............................190 5.3.3 Cables..............................190 5.3.4 Settings in BIOS..........................191 5.4 One Automation Panel 800 system via onboard SDL................192 5.4.1 Base system requirements......................... 192 5.4.2 Cables..............................192 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 6 8.2 Problems and properties of subsequent production batches..............216 Chapter 4 Software....................217 1 BIOS options..............................217 1.1 General information..........................217 1.2 BIOS Setup and boot procedure......................217 1.2.1 BIOS Setup keys..........................219 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 7 2.6 Upgrade problems............................ 273 3 Microsoft DOS..............................274 3.1 Order data..............................274 3.2 Known problems............................274 3.3 Resolutions and color depths........................274 4 Windows XP Professional..........................275 4.1 General information..........................275 4.2 Order data..............................275 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 8 9.4.7 Changing additional UPS settings...................... 294 9.4.8 Procedure following power failure...................... 296 10 B&R Automation Device Interface (ADI) Development Kit................297 11 B&R Automation Device Interface (ADI) .NET SDK..................299 12 B&R Key Editor............................301 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 9 5.4.1 General information..........................320 5.4.2 Order data............................320 5.4.3 Technical data.............................320 5.4.4 Temperature/Humidity diagram......................322 5.4.5 Dimensions............................322 5.4.6 Benchmark............................323 5.5 5CFCRD.xxxx-03............................324 5.5.1 General information..........................324 5.5.2 Order data............................324 5.5.3 Technical data.............................324 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 10 9 Uninterruptible power supply......................... 346 9.1 Features..............................346 9.2 Requirements............................346 9.3 5AC600.UPSI-00............................347 9.3.1 General information..........................347 9.3.2 Order data............................347 9.3.3 Technical data.............................347 9.3.4 Installation............................347 9.4 5AC600.UPSB-00............................. 349 9.4.1 General information..........................349 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 11 12.5.1 5CASDL.0xx0-13..........................374 12.6 USB cables.............................378 12.6.1 5CAUSB.00xx-00..........................378 12.7 RS232 cables............................379 12.7.1 9A0014.xx............................379 12.8 Internal supply cable..........................381 12.8.1 5CAMSC.0001-00..........................381 13 HDD replacement disk tray..........................382 13.1 5AC801.FRAM-00...........................382 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 12 13 Installing the ready relay /2 in the add-on UPS slot..................413 13.1 Procedure............................... 413 Appendix A ......................415 1 Maintenance Controller Extended (MTCX)....................415 1.1 Temperature monitoring - Fan control..................... 415 2 Connecting an external device to the mainboard..................417 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 13: Chapter 1 General Information

    • First version 1.05 24-Mar-10 • Renamed documentation "Automation PC 810 with BM45 CPU board" to "Automation PC 810 with GM45 CPU board". • Corrected Table 17 "Monitor/Panel interface - RGB, DVI, SDL" on page 51. • Corrected Figure 2 "Configuration - Optional components" on page 26.
  • Page 14 SDL (Smart Display Link / DVI)" on page 51. "5AC801.SDL0-00" on page 166 1.36 06-Feb-14 • Updated GOST-R certification information in the technical data. • Updated section "GOST-R" on page 306. Table 1: Manual history Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 15 Revised pinout of 5AC801.RDYR.00 ready relay, see "5AC801.RDYR-00" on page 169. • Revised pinout of 5AC801.RDYR.01 ready relay, see "5AC801.RDYR-01" on page 170. • Updated section "Automation Runtime" on page 285. Table 1: Manual history Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 16: Safety Guidelines

    Electronic devices are never completely failsafe. If the programmable control system, operating/monitoring device or uninterruptible power supply fails, the user is responsible for ensuring that other connected devices, e.g. motors, are brought to a secure state. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 17: Transport And Storage

    (e.g. diskette, CD-ROM, USB flash drive, etc.), a network connection or the Internet. The user is responsible for assessing these dangers, implementing preventive measures such as virus protection programs, firewalls, etc. and making sure that software is only obtained from trusted sources. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 18: Environmentally Friendly Disposal

    Batteries and rechargeable batteries Cables Cardboard box / Paper packaging Cardboard box / Paper recycling Plastic packaging Plastic recycling Table 2: Environmentally friendly separation of materials Disposal must comply with applicable legal regulations. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 19: Organization Of Safety Notices

    For 6 to 30 mm ±0.2 mm For 30 to 120 mm ±0.3 mm For 120 to 400 mm ±0.5 mm For 400 to 1000 mm ±0.8 mm Table 4: Range of nominal sizes Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 20: Overview

    5AC801.HDDI-02 160 GB SATA hard disk, slide-in compact, 24/7 operation with extended temperature range. Note: please see the manual for information about using this hard disk Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 21 SDL flex cable with extender, 43 m Serial adapters 5AC600.485I-00 RS232/422/485 interface, for installation in an APC620, APC810 or PPC700 5AC600.CANI-00 CAN interface; for installation in an APC620, APC810 or PPC700 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 22 Microsoft OEM Windows XP Professional Service Pack 2c, CD, multilingual. Only available with a new device. 5SWWXP.0600-ENG Windows XP Professional SP3 - English - CD 5SWWXP.0600-GER Windows XP Professional SP3 - German - CD 5SWWXP.0600-MUL Windows XP Professional SP3 - Multilingual - CD Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 23: Chapter 2 Technical Data

    PCI and/or PCI Express cards ensure the optimum design for any type of installation – a perfect fit that doesn't waste valuable space in the control cabinet. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 24: Features

    • CPU board • Heat sink • Main memory • Fan kit • Drive (mass storage device such as CompactFlash card or hard disk) for the operating system • Software Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 25: Configuration - Base System

    CPU board Select 1 5PC800.BM45-00 5PC800.BM45-01 Heat sinks Select 1 5AC801.HS00-01 Main memory Select one or two 5MMDDR.2048-02 - 2 GB 5MMDDR.4096-02 - 4 GB Figure 1: Base system configuration Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 26: Configuration - Optional Components

    5SWWXP.0600-ENG 5SWWI7. 633-ENG 5SWWXP.0600-GER 5SWWI7. 733-MUL 5SWWXP.0600-MUL 5SWWI7. 833-MUL Windows 7 Microsoft DOS 5SWWI7.1 00-ENG 5SWWI7.1100-ENG 9S0000.01-010 5SWWI7.1 00-GER 5SWWI7.1100-GER 9S0000.01-020 5SWWI7.1 00-MUL 5SWWI7.1300-MUL Figure 2: Configuration - Optional components Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 27: Complete System

    What must be considered when determining the maximum ambient temperature? • Operating the Ethernet interfaces (ETH1/ETH2) in 10/100 Mbit or 1 Gbit mode • The revision of the heat sink being used Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 28: Maximum Ambient Temperature

    1) With horizontal mounting, the maximum ambient temperature must be reduced by 5°C! 2) Only possible with a CompactFlash card from B&R that is compatible with the device. Table 5: Ambient temperature with a fan kit Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 29: Minimum Ambient Temperature

    The temperature measured approximates the immediate ambient temperature but may also be influenced by neighboring components. The ADI driver that includes the B&R Control Center is available in the Downloads section of the B&R website (www.br-automation.com). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 30 Slide-in drive 1 temperature (sensor integrated in the slide-in slot) Depends on the drive Slide-in drive 2 Slide-in drive 2 temperature (sensor integrated in the slide-in slot) Depends on the drive Table 6: Temperature sensor locations Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 31: Humidity Specifications

    The specifications listed correspond to the relative humidity at an ambient temperature of 30°C. More detailed information about specific temperature-dependent humidity values can be found in the technical data for the indi- vidual components. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 32: Power Management

    +12 V. The optional add-on UPS (with battery unit) is supplied with 15 V and provides an uninterrupted power supply of the 15 V bus during a power failure. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 33: Power Calculation With 5Pc810.Sx01-00 Revision >= D0

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 8: 1-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 34: Power Calculation With 5Pc810.Sx01-00 Revision < D0

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 9: 1-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 35: Power Calculation With 5Pc810.Sx02-00 Revision >= D0

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 10: 2-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 36: Power Calculation With 5Pc810.Sx02-00 Revision < D0

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 11: 2-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 37: Power Calculation With 5Pc810.Sx03-00

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 12: 3-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 38: Power Calculation With 5Pc810.Sx05-00

    1) The total performance of one PCI / PCIe card per PCI slot (= sum of power consumptions for each voltage area) may not exceed the limits stated for opera- tion with a fan kit. Table 13: 5-slot APC variant - Power calculation table Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 39: Serial Number Sticker

    Figure 5: Serial number sticker (front) A sticker with detailed information about the installed components can also be found on the back of the mounting plate. Figure 6: Serial number sticker (back) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 40 Serial number entered here e.g. A3C70168444 Switching to the option "Serial number" List of installed components shown after searching for a serial number Figure 7: A3C70168444 - Example of serial number search Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 41: Block Diagrams

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 8: 5PC810.SX01-00 + 5PC810.BX01-00 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 42: 5Pc810.Sx01-00 System Unit + 5Pc810.Bx01-01 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 9: 5PC810.SX01-00 + 5PC810.BX01-01 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 43: 5Pc810.Sx02-00 System Unit + 5Pc810.Bx02-00 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 10: 5PC810.SX02-00 + 5PC810.BX02-00 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 44: 5Pc810.Sx02-00 System Unit + 5Pc810.Bx02-01 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 11: 5PC810.SX02-00 + 5PC810.BX02-01 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 45: 5Pc810.Sx03-00 System Unit + 5Pc810.Bx03-00 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 12: 5PC810.SX03-00 + 5PC810.BX03-00 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 46: 5Pc810.Sx05-00 System Unit + 5Pc810.Bx05-00 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 13: 5PC810.SX05-00 + 5PC810.BX05-00 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 47: 5Pc810.Sx05-00 System Unit + 5Pc810.Bx05-01 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3.3 volts Switching Piezzo Buzzer DC/DC +12 volts Switching Interface directed outwards Interface - Optional or internal Figure 14: 5PC810.SX05-00 + 5PC810.BX05-01 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 48: 5Pc810.Sx05-00 System Unit + 5Pc810.Bx05-02 Bus Unit

    DC/DC supply Isolated 3-pin DC/DC +3,3 Volt Switching Piezzo Buzzer DC/DC +12 Volt Switching Interface directed outwards Interface - Optional or internal Figure 15: 5PC810.SX05-00 + 5PC810.BX05-02 - Block diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 49: Device Interfaces And Slots

    The M4 self-locking nut must be used, for example, to fasten a copper strip to a central grounding point in the control cabinet or system where the APC810 is installed. The largest possible conductor cross section should be used (at least 2.5 mm²). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 50: Com1 Serial Interface

    Table 16: COM2 - Pinout The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 51: Monitor/Panel Interface - Sdl (Smart Display Link / Dvi)

    +5 V power supply C5 ANALOG GND G and B signals) Ground (return for +5 V, HSync Ground and VSync) Table 18: DVI interface - Pinout Protected internally by a multifuse. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 52 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 Table 20: Cable lengths and resolutions for DVI transmission The maximum cable length for DVI transfer is limited to 5 m due to the USB specification. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 53: Ethernet 1 (Eth1)

    A special driver is required in order to operate the Intel 82567 Ethernet controller. Drivers for approved operating systems are available in the Downloads section of the B&R website www.br-automation.com. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 54: Ethernet 2 (Eth2)

    A special driver is required in order to operate the Intel 82573L Ethernet controller. Drivers for approved operating systems are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 55: Usb Interfaces (Usb1, 2, 3, 4, 5)

    The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Each USB port is protected by a maintenance-free "USB current-limiting circuit breaker" (max. 1 A). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 56: Mic, Line In, Line Out

    An optional add-on interface (e.g. CAN, RS485) can be installed here. See also "Add-on interfaces (IF option)" on page 172. Add-on interface slot Model number Short description Serial port adapter IF option 5AC600.CANI-00 Add-on CAN interface 5AC600.458I-00 Add-on RS232/422/458 interface Table 26: Add-on interface slot Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 57: Add-On Ups Slot

    DVI and SDL, but without RGB signals. In addition, the 5AC801.RDYR-00 ready relay can also be installed in the APC810. Information: AP Link cards can only be installed with system units 5PC810.SX02-00, 5PC810.SX03-00 and 5PC810.SX05-00. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 58: Card Slots (Pci / Pcie)

    PCIe PCIe PCIe 5PC810.BX05-02 32-bit and 64-bit PCI 32-bit and 64-bit PCI 32-bit and 64-bit PCI 32-bit and 64-bit PCI 32-bit and 64-bit PCI Table 28: Overview of 64-bit cards Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 59 Card slot 3 Card slot 3 Card slot 2 Card slot 2 Card slot 2 Card slot 1 Card slot 1 Card slot 1 Card slot 1 5PC810.SX01-00 5PC810.SX01-00 5PC810.SX02-00 5PC810.SX03-00 5PC810.SX05-00 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 60: Led Status Indicators

    The factory default switch position represents the optimal BIOS default values for this system and should therefore not be changed. The position of the CMOS profile switch is displayed in BIOS Setup and in the B&R ADI Control Center. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 61: Power Button

    Pushing the reset button triggers a hardware and PCI reset. The APC810 is restarted (cold restart). Pressing the reset button does not reset the MTCX processor. Table 32: Reset button Warning! A system reset can result in lost data! Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 62: Battery

    From the point when battery capacity is recognized as insufficient, data buffering is intact for approximately another 500 hours. When replacing the battery, data is buffered for approximately 10 minutes by a gold leaf capacitor. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 63: Hardware Security Key (Dongle)

    Hardware security key A hardware security key (dongle) can be inserted behind the black cover. Table 35: Hardware security key Warning! Turn off power before removing or adding the hardware security key. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 64: Compactflash Slot 1

    Since the Intel GM45 chipset used on 5PC800.BM45-0x systems no longer supports an IDE (PATA) channel, the CF2 slot is not supported. CompactFlash slot (CF2) Table 37: CompactFlash slot (CF2) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 65: Slide-In Slot 1

    Information: The required drivers are available for the operating system being used and can be downloaded from the B&R website. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 66: Slide-In Compact Slot

    The SATA I interface allows disks to be replaced during operation (hot plugging). In order to take advantage of this capability, this feature must be supported by the operating system. For information about installing/replacing a slide-in compact drive, see "Procedure" on page 387. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 67: Individual Components

    RS232/422/485 interface, for installation in an APC620, APC810 or PPC700 5AC600.CANI-00 CAN interface; for installation in an APC620, APC810 or PPC700 Uninterruptible power supply Table 41: 5PC810.SX01-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 68 USB2, USB4 (max. 500 mA) USB1, USB3 (max. 1 A) Warning Heat sink seal Heat sinks * Depends on the bus unit used Figure 19: 5PC810.SX01-00 - Interfaces on top Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 69 Type Renata 950 mAh Service life 2½ years Removable Yes, accessible behind the orange front door Execution Lithium ion Power button Reset button Buzzer Table 42: 5PC810.SX01-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 70 Insert for fan kit Electrical characteristics Nominal voltage 24 VDC ±25% Nominal current Starting current Typ. 7 A, max. 50 A for <300 µs Electrical isolation Table 42: 5PC810.SX01-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 71 The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). There may be visible deviations in the color and surface appearance depending on the process or batch. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 72 3.1.1.5 Dimensions ø5.4 ø11 65.5 "A" Information: Measurement “A” depends on which heat sink is used. Model number Entry in mm 5AC801.HS00-00 12.8 5AC801.HS00-01 5AC801.HS00-02 12.8 Figure 21: 5PC810.SX01-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 73 Technical data • Individual components 3.1.1.6 Drilling template Mounting plate outline (APC810) Figure 22: 5PC810.SX01-00 - Drilling template Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 74: 5Pc810.Sx02-00

    RS232/422/485 interface, for installation in an APC620, APC810 or PPC700 5AC600.CANI-00 CAN interface; for installation in an APC620, APC810 or PPC700 Uninterruptible power supply Table 43: 5PC810.SX02-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 75 USB2, USB4 (max. 500 mA) USB1, USB3 (max. 1 A) Warning Heat sink seal Heat sinks * Depends on the bus unit used Figure 23: 5PC810.SX02-00 - Interfaces on top Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 76 HazLoc Class 1 Division 2 ATEX Zone 22 GOST-R Controller Boot loader BIOS Real-time clock Battery backed Power failure logic Controller MTCX Buffer time 10 ms Table 44: 5PC810.SX02-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 77 -20 to 60°C Transport -20 to 60°C Relative humidity Operation Depends on the component Storage Depends on the component Transport Depends on the component Table 44: 5PC810.SX02-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 78 The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). There may be visible deviations in the color and surface appearance depending on the process or batch. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 79 20.3 ø5.4 ø11 "A" Information: Measurement “A” depends on which heat sink is used. Model number Entry in mm 12.8 5AC801.HS00-00 5AC801.HS00-01 12.8 5AC801.HS00-02 110.5 Figure 25: 5PC810.SX02-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 80 Technical data • Individual components 3.1.2.6 Drilling template Mounting plate outline (APC810) 20.3 90.3 110.5 Figure 26: 5PC810.SX02-00 - Drilling template Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 81: 5Pc810.Sx03-00

    RS232/422/485 interface, for installation in an APC620, APC810 or PPC700 5AC600.CANI-00 CAN interface; for installation in an APC620, APC810 or PPC700 Uninterruptible power supply Table 45: 5PC810.SX03-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 82 USB2, USB4 (max. 500 mA) USB1, USB3 (max. 1 A) Warning Heat sink seal Heat sinks * Depends on the bus unit used Figure 27: 5PC810.SX03-00 - Interfaces on top Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 83 Boot loader BIOS Real-time clock Battery backed Power failure logic Controller MTCX Buffer time 10 ms Graphics Controller Depends on the CPU board being used Table 46: 5PC810.SX03-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 84 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Transport 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Table 46: 5PC810.SX03-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 85 The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). There may be visible deviations in the color and surface appearance depending on the process or batch. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 86 30.5 ø5.4 ø11 125.5 "A" Information: Measurement “A” depends on which heat sink is used. Model number Entry in mm 12.8 5AC801.HS00-00 5AC801.HS00-01 12.8 5AC801.HS00-02 Figure 29: 5PC810.SX03-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 87 Technical data • Individual components 3.1.3.6 Drilling template Mounting plate outline (APC810) 30.5 100.5 Figure 30: 5PC810.SX03-00 - Drilling template Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 88: 5Pc810.Sx05-00

    RS232/422/485 interface, for installation in an APC620, APC810 or PPC700 5AC600.CANI-00 CAN interface; for installation in an APC620, APC810 or PPC700 Uninterruptible power supply Table 47: 5PC810.SX05-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 89 USB2, USB4 (max. 500 mA) USB1, USB3 (max. 1 A) Warning Heat sink seal Heat sinks * Depends on the bus unit used Figure 31: 5PC810.SX05-00 - Interfaces on top Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 90 192 kB (e.g. for Automation Runtime, see AS help documentation) Memory Type Depends on the CPU board being used Memory size Depends on the CPU board being used Table 48: 5PC810.SX05-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 91 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Shock Operation 15 g, 11 ms Storage 30 g, 15 ms Transport 30 g, 15 ms Table 48: 5PC810.SX05-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 92 ø5.4 ø11 185.9 "A" Information: Measurement “A” depends on which heat sink is used. Model number Entry in mm 12.8 5AC801.HS00-00 5AC801.HS00-01 12.8 5AC801.HS00-02 191.4 Figure 33: 5PC810.SX05-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 93 Technical data • Individual components 3.1.4.6 Drilling template Mounting plate outline (APC810) 25.7 95.7 165.7 191.4 Figure 34: 5PC810.SX05-00 - Drilling template Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 94: Bus Units

    Figure 35: 1-slot bus units 2 PCI slots 1 PCIe slot 1 PCI slot 5PC810.BX02-01 5PC810.BX02-00 Figure 36: 2-slot bus units 1 PCIe slot 2 PCI slots 5PC810.BX03-00 Figure 37: 3-slot bus units Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 95: Order Data

    33 MHz 33 MHz 33 MHz 33 MHz PCI to PCI bridge Yes, slots 4 and 5 Table 50: 5PC810.BX01-00, 5PC810.BX01-01, 5PC810.BX02-00, 5PC810.BX02-01, 5PC810.BX03-00, 5PC810.BX05-00, 5PC810.BX05-01, 5PC810.BX05-02 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 96 Due to mechanical limitations, a 64-bit PCI card cannot be inserted in every system unit or card slot. A table in the user's manual provides an overview of the slots where 64-bit cards can be inserted. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 97: Gm45 Cpu Boards

    Real-time clock Precision At 25°C: typ. 12 ppm (1 seconds) per day Battery backed Memory slot Type DDR3 Memory size Max. 8 GB Table 52: 5PC800.BM45-00, 5PC800.BM45-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 98 Yes, although applies only if all components installed within the complete system have this certification At max. specified ambient temperature: typ. 58 ppm (5 seconds) - worst-case 220 ppm (19 seconds). Allocated in main memory. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 99: Heat Sink

    218 mm Depth 28 mm Weight Approx. 2000 g Table 54: 5AC801.HS00-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 100: Main Memory

    Table 56: 5MMDDR.2048-02, 5MMDDR.4096-02 - Technical data Yes, although applies only if all components installed within the complete system have this certification Information: A main memory module can only be replaced at B&R. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 101: Drives

    Max. 150 MB/s (Ultra DMA mode 5) Positioning time Minimum (track to track) 1 ms Nominal (read only) 12.5 ms Maximum (read only) 23 ms Table 58: 5AC801.HDDI-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 102 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.6.1.4 Temperature humidity diagram Operation Temperature [°C] Figure 39: 5AC801.HDDI-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 103: 5Ac801.Hddi-02

    Maximum (read only) 22 ms Environmental conditions Temperature Operation -15 to 80°C 24-hour operation -15 to 80°C Storage -40 to 95°C Transport -40 to 95°C Table 60: 5AC801.HDDI-02 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 104 Humidity gradient: Maximum 15% per hour. Maximum humidity at 29°C. Maximum humidity at 40°C. Slide-in compact installation. 3.6.2.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 40: 5AC801.HDDI-02 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 105: 5Ac801.Hddi-03

    Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Minimum (track to track) 1 ms Nominal (read only) 14 ms Maximum (read only) 30 ms Table 62: 5AC801.HDDI-03 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 106 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. Slide-in compact installation. 3.6.3.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 41: 5AC801.HDDI-03 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 107: 5Ac801.Hddi-04

    Maximum (read only) 21 ms Environmental conditions Temperature Operation 0 to 60°C 24-hour operation 0 to 60°C Storage -40 to 70°C Transport -40 to 70°C Table 64: 5AC801.HDDI-04 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 108 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. Slide-in compact installation. 3.6.4.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 42: 5AC801.HDDI-04 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 109: 5Ac801.Ssdi-00

    MTBF 2,000,000 hours Power on/off cycles 50,000 S.M.A.R.T. support Interface SATA Maintenance None Continuous reading Max. 250 MB/s Continuous writing Max. 170 MB/s Table 66: 5AC801.SSDI-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 110 Table 66: 5AC801.SSDI-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 111 Technical data • Individual components 3.6.5.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 43: 5AC801.SSDI-00 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 112 Figure 44: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic read 1024 2048 4096 8192 Transfer size [kB] 5AC801.SSDI-00 5AC801.HDDI-00 Figure 45: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic write Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 113: 5Ac801.Ssdi-01

    Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 475 MB/s with SATA 6 Gbit/s Max. 245 MB/s with SATA 3 Gbit/s Table 68: 5AC801.SSDI-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 114 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.6.6.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 46: 5AC801.SSDI-01 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 115: 5Ac801.Ssdi-02

    Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 520 MB/s with SATA 6 Gbit/s Max. 260 MB/s with SATA 3 Gbit/s Table 70: 5AC801.SSDI-02 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 116 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.6.7.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 47: 5AC801.SSDI-02 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 117: 5Ac801.Ssdi-03

    MLC flash Guaranteed data volume Guaranteed 35 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 72: 5AC801.SSDI-03, 5AC801.SSDI-03 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 118 IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.6.8.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 48: 5AC801.SSDI-03 ≤ Rev. C0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 119 Technical data • Individual components Operation Temperature [°C] Figure 49: 5AC801.SSDI-03 ≥ Rev. D0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 120: 5Ac801.Ssdi-04

    <1 unrecoverable error in 10 bit read accesses MTBF 1,500,000 hours S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 510 MB/s Sequential write Max. 450 MB/s Table 74: 5AC801.SSDI-04, 5AC801.SSDI-04 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 121 IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.6.9.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 50: 5AC801.SSDI-04 ≤ Rev. C0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 122 Technical data • Individual components Operation Temperature [°C] Figure 51: 5AC801.SSDI-04 ≥ Rev. D0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 123: 5Ac801.Ssdi-05

    <1 unrecoverable error in 10 bit read accesses MTBF 1,500,000 hours S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 510 MB/s Sequential write Max. 460 MB/s Table 76: 5AC801.SSDI-05 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 124 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.6.10.4 Temperature humidity diagram Operation Temperature [°C] Figure 52: 5AC801.SSDI-05 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 125: 5Ac801.Adas-00

    Height 172.5 mm Depth 150 mm Weight 328 g Table 78: 5AC801.ADAS-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 126: 5Ac801.Hdds-00

    Max. 150 MB/s (Ultra DMA mode 5) Positioning time Minimum (track to track) 1 ms Nominal (read only) 12.5 ms Maximum (read only) 23 ms Table 80: 5AC801.HDDS-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 127 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.6.12.4 Temperature humidity diagram Operation Temperature [°C] Figure 53: 5AC801.HDDS-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 128: 5Ac801.Dvds-00

    Max. 19 seconds (from 0 rpm to read access) Max. 19 seconds (from 0 rpm to read access) Access time Average of 130 ms Average of 140 ms Table 82: 5AC801.DVDS-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 129 Figure 54: 5AC801.DVDS-00 - Temperature humidity diagram 3.6.13.5 Hot plugging Hardware revision B0 of the 5AC801.DVDS-00 slide-in DVD-ROM does not offer SATA hot plugging functionality. Hot plugging is possible for other hardware revisions. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 130: 5Ac801.Dvrs-00

    Max. 14 seconds (from 0 rpm to read access) Max. 15 seconds (from 0 rpm to read access) Access time On average 140 ms (24x) On average 150 ms (8x) Table 84: 5AC801.DVRS-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 131 Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). Drive surface temperature. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 132 Technical data • Individual components 3.6.14.4 Temperature humidity diagram Storage Operation Temperature [°C] Figure 55: 5AC801.DVRS-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 133: 5Acpci.raic-03

    Optional accessories Drives 5ACPCI.RAIC-04 160 GB SATA hard disk, replacement part for 5ACPCI.RAIC-03; note: Please see the manual for information about using this hard disk. Table 85: 5ACPCI.RAIC-03 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 134 Operation -300 to 3048 m Storage -300 to 12192 m Mechanical characteristics Installation Fixed Dimensions Width 70 mm Length 100 mm Height 9.5 mm Table 86: 5ACPCI.RAIC-03 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 135 The 160 GB 5ACPCI.RAIC-04 SATA HDD is available as a replacement hard disk. For instructions on replacing the drive, see 7 "Maintenance and service", section 11 "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 410. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 136: 5Acpci.raic-04

    5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Transport 5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Table 88: 5ACPCI.RAIC-04 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 137 Operation in areas prone to vibration and shock can affect performance negatively (reduction of transfer rate). 3.6.16.4 Temperature humidity diagram Operation Temperature [°C] Figure 58: 5ACPCI.RAIC-04 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 138: 5Acpci.raic-05

    Drives 5MMHDD.0250-00 250 GB SATA hard disk; replacement for 5AC801.HDDI-03 and 5ACPCI.RAIC-05; note: please see the manual for information about using this hard disk Table 89: 5ACPCI.RAIC-05 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 139 20°C per hour. Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 140 The 250 GB 5MMHDD.0250-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 410. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 141: 5Acpci.raic-06

    Model number Short description Figure Drives 5ACPCI.RAIC-06 PCI RAID System 2x 500 GB - SATA Optional accessories Drives 5MMHDD.0500-00 500 GB hard disk - SATA Table 91: 5ACPCI.RAIC-06 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 142 1000 g and 2 ms duration; no unrecoverable errors Altitude Operation -305 to 3048 m Storage -305 to 12192 m Mechanical characteristics Installation Fixed Table 92: 5ACPCI.RAIC-06 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 143 The 500 GB 5MMHDD.0500-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 410. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 144: 5Mmhdd.0250-00

    Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Minimum (track to track) 1 ms Nominal (read only) 14 ms Maximum (read only) 30 ms Table 94: 5MMHDD.0250-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 145 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. 3.6.19.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 63: 5MMHDD.0250-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 146: 5Mmhdd.0500-00

    Typ. 3.5 s (from 0 rpm to read access) Service life 5 years MTBF 1,000,000 POH S.M.A.R.T. support Interface SATA Access time 5.5 ms Supported transfer modes SATA II Table 96: 5MMHDD.0500-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 147 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. 3.6.20.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 64: 5MMHDD.0500-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 148: 5Mmssd.0060-00

    4k write Typical 23,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 98: 5MMSSD.0060-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 149 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.6.21.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 65: 5MMSSD.0060-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 150: 5Mmssd.0060-01

    SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Environmental conditions Temperature Operation 0 to 70°C -30 to 85°C Storage -40 to 85°C Transport -40 to 85°C Table 100: 5MMSSD.0060-01, 5MMSSD.0060-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 151 Yes, although applies only if all components installed within the complete system have this certification. IOPS: Random read and write input/output operations per second. TBW: Terabytes written. 3.6.22.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 66: 5MMSSD.0060-01 ≤ Rev. C0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 152 Technical data • Individual components Operation Temperature [°C] Figure 67: 5MMSSD.0060-01 ≥ Rev. D0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 153: 5Mmssd.0128-01

    MLC flash Guaranteed data volume Guaranteed 74 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 102: 5MMSSD.0128-01, 5MMSSD.0128-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 154 Yes, although applies only if all components installed within the complete system have this certification. IOPS: Random read and write input/output operations per second. TBW: Terabytes written. 3.6.23.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 68: 5MMSSD.0128-01 ≤ Rev. C0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 155 Technical data • Individual components Operation Temperature [°C] Figure 69: 5MMSSD.0128-01 ≥ Rev. D0 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 156: 5Mmssd.0180-00

    4k write Typical 60,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 104: 5MMSSD.0180-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 157 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.6.24.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 70: 5MMSSD.0180-00 - Temperature humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 158: 5Mmssd.0256-00

    Endurance MLC flash Guaranteed data volume Guaranteed 148 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 106: 5MMSSD.0256-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 159 Yes, although applies only if all components installed within the complete system have this certification. IOPS: Random read and write input/output operations per second. TBW: Terabytes written. 3.6.25.4 Temperature/Humidity diagram Operation Temperature [°C] Figure 71: 5MMSSD.0256-00 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 160: Fan Kit

    Service life 29,000 hours at 70°C 95,000 hours at 20°C Type Double ball bearings Certification cULus HazLoc Class 1 Division 2 ATEX Zone 22 GOST-R Table 108: 5PC810.FA01-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 161: 5Pc810.Fa02-01

    General information Number of fans Speed Max. 4300 rpm ±12.5% Noise level 32 dB Service life 60,000 hours (at 40°C) Type Double ball bearings Table 110: 5PC810.FA02-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 162 Yes, although applies only if all components installed within the complete system have this certification For information about installing/replacing fan kits, see chapter "Maintenance and service", section 6 "Installing and replacing fan kits" on page 391. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 163: 5Pc810.Fa03-00

    Fan 1: 70 mm Fan 2: 80 mm Height Fan 1: 70 mm Fan 2: 80 mm Depth Fan 1: 15 mm Fan 2: 15 mm Table 112: 5PC810.FA03-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 164 Technical data • Individual components For information about installing/replacing fan kits, see chapter "Maintenance and service", section 6 "Installing and replacing fan kits" on page 391. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 165: 5Pc810.Fa05-00

    Depth 15 mm Table 114: 5PC810.FA05-00 - Technical data For information about installing/replacing fan kits, see chapter "Maintenance and service", section 6 "Installing and replacing fan kits" on page 391. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 166: Ap Link Cards

    Automation Panel Link interfaces 5AC801.SDL0-00 Smart Display Link/DVI-D transmitter Table 115: 5AC801.SDL0-00 - Order data 3.8.1.3 Technical data Product ID 5AC801.SDL0-00 General information Certification GOST-R Table 116: 5AC801.SDL0-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 167 5CASDL.0250-00 5CASDL.0250-00 5CASDL.0250-00 5CASDL.0250-03 5CASDL.0250-03 5CASDL.0250-03 5CASDL.0250-03 5CASDL.0300-00 5CASDL.0300-00 5CASDL.0300-03 5CASDL.0300-03 5CASDL.0300-13 5CASDL.0300-13 5CASDL.0300-13 5CASDL.0300-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 5CASDL.0400-13 Table 118: Cable lengths and resolutions for SDL transmission Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 168 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 Table 119: Cable lengths and resolutions for DVI transmission The maximum cable length for DVI transfer is limited to 5 m due to the USB specification. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 169: 5Ac801.Rdyr-00

    3.8.2.1 General information Since the 5AC801.RDYR-00 ready relay switches the relay contacts as soon as the B&R Automation PC 810 has booted and is supplied internally with all voltages, it is possible to connect additional devices to the relay that will also be switched on.
  • Page 170: Ready Relay

    3.9.2 General information Since the 5AC801.RDYR-01 ready relay switches the relay contacts as soon as the B&R Automation PC 810 has booted and is supplied internally with all voltages, it is possible to connect additional devices to the relay that will also be switched on.
  • Page 171: Contents Of Delivery

    Ready relay Power supply cable (internal) Spacer ring Label strip Mounting bracket 3x Torx screw (T6) Spacer bolt Spacer bolt 14 mm 16 mm Figure 78: 5AC801.RDYR-01 - Contents of delivery Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 172: Add-On Interfaces (If Option)

    Bosch CC770 (compatible with Intel 82527 CAN controller) Design 9-pin male DSUB connector Terminating resistor Type Can be enabled or disabled using a sliding switch Default setting Disabled Table 125: 5AC600.CANI-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 173 CAN networks are cabled using a bus structure where both ends of the bus are equipped with terminating resistors. The add-on CAN interface has an integrated terminating resistor (factory setting: disabled with the setting "Off"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 174 Due to the dual core processors, driver version 2.36 of INACAN.SYS included in the PVI 2.6.0.3105 installer is required for operation. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 175: 5Ac600.485I-00

    Legacy devices - COM E). It is possible for conflicts with other resources to occur when changing this setting. 3.10.3.6 RS232 - Bus length and cable type The maximum transfer rate of 115 kbit/s depends on the type of cable being used. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 176 3.10.3.8 When operated as an RS485 interface When operated in this mode, the pins of the RS422 default interface (1, 4, 6 and 9) must be used. Pins should be connected as shown. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 177 Table 139: RS422 - Cable requirements 3.10.3.10 Contents of delivery The screws included in the mounting kit are used for installation. Figure 83: 5AC600.485I-00 - Contents of delivery / installation material Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 178: Chapter 3 Installation

    • The wall or control cabinet must be able to withstand four times the total weight of the device. • The flex radius of connected cables (DVI, SDL, USB, etc.) must not be exceeded. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 179: Mounting Orientation

    Figure 86: Horizontal mounting orientation In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 180. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 180: Spacing For Air Circulation

    In order to guarantee sufficient air circulation, allow the specified amount of space above, below, to the side and behind the Automation PC 810 devices. The minimum specified spacing is indicated in the following diagram. This applies to all Automation PC 810 variants.
  • Page 181: Cable Connections

    The maximum torque for the locating screws is 0.5 Nm. Locating screws Flex radius Locating screws Figure 88: Flex radius - Cable connection Information: The specified flex radius is listed in the technical data for the respective cable. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 182: Grounding Concept

    • Note the line shielding concept. All data cables connected to the device must be shielded. Symbol indicating functional ground on the B&R device: Ground connection Min. 2.5 m m² Control cabinet Supply voltage Grounding strip Min. .5 m m² Figure 89: Grounding concept Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 183: General Instructions For Performing Temperature Testing

    A separate application can be developed if it is necessary to collect historical data. Information: Software development kits such as the ADI .NET SDK are available on the B&R website (www.br- automation.com). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 184: Evaluating With The Burnintest Tool From Passmark

    The following screenshots are based on Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD. Figure 90: Settings for Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 185 Information: Serial loopback plugs are relatively easy to create. Simply connect several pins on the serial interface with wires. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 186: Evaluating Temperatures In Operating Systems Other Than Windows

    66°C 76°C Board ETH2 52°C 67°C 77°C Board power supply 51°C 66°C 76°C ETH2 65°C 80°C 90°C Power supply 51°C 66°C 76°C Table 140: Evaluation example using a 2-slot APC810 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 187: Connection Examples

    The following table lists the AP900 devices that can be connected on the same line with an AP800 device. Automation Panel 800 Automation Panel 900 5AP820.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 5AP880.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 Table 141: Selecting display units Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 188: One Automation Panel 900 System Via Onboard Dvi

    USB 2.0 connection cable Type A - Type B, 1.8 m 1.8 m ±30 mm 5CAUSB.0050-00 USB 2.0 connection cable Type A - Type B, 5 m 5 m ±50 mm Table 144: Cables for DVI configurations Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 189: Possible Automation Panel Devices, Resolutions And Segment Lengths

    Information: When transferring data via DVI, it is not possible to read statistical values from Automation Panel 900 devices. 5.2.5 BIOS settings No special BIOS settings are necessary for operation. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 190: One Automation Panel 900 System Via Onboard Sdl

    5CASDL.0400-13 SDL flex cable with extender, 40 m 40 m ±380 mm 5CASDL.0430-13 SDL flex cable with extender, 43 m 43 m ±410 mm Table 148: Cables for SDL configurations Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 191: Settings In Bios

    Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 192: One Automation Panel 800 System Via Onboard Sdl

    The following table lists the relationship between segment lengths and maximum resolution depending on the SDL cable being used: Cables Resolution Segment length [m] 1024 x 768 5CASDL.0018-20 5CASDL.0050-20 5CASDL.0100-20 5CASDL.0150-20 Table 152: Cable lengths and resolutions for SDL transmission Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 193: Settings In Bios

    Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 194: One Ap900 And One Ap800 Via Onboard Sdl

    For detailed information regarding cables, see the chapter "Accessories". 5.5.4 Settings in BIOS No special BIOS settings are necessary for operation. For detailed information, see the user's manual for the B&R Industrial PC being used. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 195 Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 196: Four Automation Panel 900 Systems Via Onboard Sdl

    Connections for SDL In and SDL Out; transmission of display, touch screen, USB 1.1, matrix key and service data; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately) Table 156: Link modules 5.6.3 Cables Select an Automation Panel 900 cable from the following table. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 197: Settings In Bios

    Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 198: One Automation Panel 900 Via Sdl Ap Link

    SDL cable, 25 m 25 m ±100 mm 5CASDL.0300-00 SDL cable, 30 m 30 m ±100 mm 5CASDL.0018-03 SDL flex cable, 1.8 m 1.8 m ±20 mm Table 161: Cables for SDL configurations Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 199: Bios Settings

    Touch screen functionality COM D must be enabled in BIOS in order to operate the panel touch screen connected to the AP Link interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 200: Four Automation Panel 900 Units Via Sdl Ap Link

    APC810 AP Link SDL transmitter For Automation PC 810 Automation Panel SDL link transmitter Table 164: Link modules 5.8.3 Cables Select an Automation Panel 900 cable from the following table. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 201: Bios Settings

    Touch screen functionality COM D must be enabled in BIOS in order to operate the panel touch screen connected to the AP Link interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 202: Two Automation Panel 900 Systems Via Onboard Sdl And Sdl Ap Link

    30 m ±100 mm 5CASDL.0018-03 SDL flex cable, 1.8 m 1.8 m ±20 mm 5CASDL.0050-03 SDL flex cable, 5 m 5 m ±45 mm Table 169: Cables for SDL configurations Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 203: Settings In Bios

    COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel or AP Link interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 204: Eight Automation Panel 900 Units Via Onboard Sdl And Sdl Ap Link

    5PC810.SX01-00 5PC810.SX02-00 5PC810.SX03-00 5PC810.SX05-00 ✓ ✓ ✓ 5PC800.BM45-00 Max. UXGA ✓ ✓ ✓ 5PC800.BM45-01 Max. UXGA Table 171: Possible system unit and CPU board combinations AP Link cannot be installed. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 205: Link Modules

    5CASDL.0150-01 5CASDL.0150-01 5CASDL.0150-01 5CASDL.0150-01 5CASDL.0150-03 5CASDL.0150-03 5CASDL.0150-03 5CASDL.0150-03 5CASDL.0150-03 5CASDL.0150-03 5CASDL.0200-00 5CASDL.0200-00 5CASDL.0200-00 5CASDL.0200-00 5CASDL.0200-00 5CASDL.0200-03 5CASDL.0200-03 5CASDL.0200-03 5CASDL.0200-03 5CASDL.0200-03 5CASDL.0200-03 Table 174: Cable lengths and resolutions for SDL transmission Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 206: Settings In Bios

    COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel or AP Link interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 207: Six Ap900 And Two Ap800 Units Via Onboard Sdl And Sdl Ap Link

    5PC810.SX01-00 5PC810.SX02-00 5PC810.SX03-00 5PC810.SX05-00 ✓ ✓ ✓ 5PC800.BM45-00 Max. UXGA ✓ ✓ ✓ 5PC800.BM45-01 Max. UXGA Table 175: Possible system unit and CPU board combinations AP Link cannot be installed. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 208: Link Modules

    COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel or AP Link interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 209: Connecting Peripheral Usb Devices

    USB memory media e.g. flash drive USB drives e.g. CD-ROM drive USB input devices USB pointing devices e.g. keyboard e.g. mouse Figure 102: Local connection of USB peripheral devices on the APC810 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 210: Remote Connection To Automation Panel 900 Via Dvi

    USB input devices USB drives USB pointing devices e.g. keyboard e.g. CD-ROM drive e.g. mouse Figure 104: Remote connection of USB peripheral devices on the APC800/900 via SDL Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 211: Configuring A Sata Raid Set

    Enter Selects an item or opens a submenu Returns to the previous menu Ctrl+E Saves any changed settings and exits setup Table 178: BIOS-relevant keys in the RAID Configuration Utility Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 212: Create Raid Set

    Figure 108: RAID Configuration Utility - Create RAID set - Striped "Auto configuration" Auto configuration optimizes all settings. "Manual configuration" Allows the first and second HDD to be specified as well as the "Chunk size" (= block size, application-dependent). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 213: Create Raid Set - Mirrored

    Previous Menu Enter Select Ctrl-E Exit First HDD Figure 110: RAID Configuration Utility - Delete RAID set An existing RAID set can be deleted using the "Delete RAID set" menu option. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 214: Rebuild Mirrored Set

    Figure 112: RAID Configuration Utility - Resolve conflicts Conflicts in a RAID set can be resolved using the "Resolve conflicts" menu option. This function is only available if the status of the hard disk is "Conflict". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 215: Low Level Format

    Individual hard disks can be configured using the "Low level format" menu option. This can only be done if a RAID set is not configured. A low level format of a hard disk takes approx. 40 minutes. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 216: Known Problems/Issues

    50 ms. The panel locking time can be configured with the B&R Key Editor. • The 5AC600.CANI-00 interface option is no longer supported beginning with Windows 7. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 217: Chapter 4 Software

    To enter BIOS Setup, press the <Del> key after the USB controller has been initialized as soon as the following message appears on the screen (during POST): "Press DEL to run SETUP". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 218 Pri Master : ST940817SM 3.AAB Ultra DMA Mode-5, S.M.A.R.T. Capable and Status OK Auto-detecting USB Mass Storage Devices .. 00 USB mass storage devices found and configured. Figure 114: GM45 Boot Screen Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 219: Bios Setup Keys

    F2 / F3 Changes the colors of BIOS Setup Resets any changes Loads and configures CMOS default values for all BIOS settings Saves and exits Exits a submenu Table 180: BIOS-relevant keys Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 220: Main

    Displays the boot counter; each restart increases None the counter by one (max. 16777215) Running time Displays the runtime in hours (max. 65535) None Table 181: GM45 Main menu - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 221: Advanced

    See "CPU board monitor" on page 241 Baseboard/Panel fea- Displays and configures device-specific settings Enter Opens the submenu tures See "Baseboard/Panel features" on page 242 Table 182: GM45 Advanced menu Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 222: Acpi Configuration

    Temperature setting for the critical trip point. which the operating system automatically shuts 100°C, 105°C, 110°C Configurable in increments of 5 degrees. down Table 183: GM45 Advanced - ACPI configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 223: Pci Configuration

    See "PCI IRQ resource exclusion" on page PCI interrupt routing Configures PCI interrupt routing Enter Opens the submenu See "PCI interrupt routing" on page 225 Table 184: GM45 Advanced - PCI configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 224 Allocated by the system - cannot be used Available Available - can be used Reserved Reserved - cannot be used Table 185: GM45 Advanced - PCI IRQ resource exclusion - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 225 Assigns the PIRQ as the 1st exclusive PCI IRQ sharing). Information: This is only displayed if a PIRQ is con- figured manually (e.g. 5). Table 186: GM45 Advanced - PCI interrupt routing - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 226: Pci Express Configuration

    This option enables or disables the PCI Express Auto Automatic assignment by BIOS and the operat- interface function. ing system Table 187: GM45 Advanced - PCI Express configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 227 Disables this function PCIE port 3. The IRQ resources available to the system are expanded when APIC mode is en- abled. Table 187: GM45 Advanced - PCI Express configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 228: Graphics Configuration

    Automatic detection and configuration using the for the LVDS channel. EDID data VGA 1x18 (002h) 640 x 480 VGA 1x18 (013h) 640 x 480 Table 188: GM45 Advanced - Graphics configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 229 DVI monitors are reconnected, even if only one of them was connected and enabled during a previ- ous boot. Table 188: GM45 Advanced - Graphics configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 230: Cpu Configuration

    "On demand clock modulation" 12.5%, 25%, 37.5%, Example: 75% results in a performance reduc- 50%, 62.5%, 75%, 87.5% tion of 25%. Table 189: GM45 Advanced - CPU configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 231: Chipset Settings

    POST code output should be routed to the PCI Routes port 80h/84h to the LPC bus bus or the LPC bus. Table 190: GM45 Advanced - Chipset settings - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 232: I/O Interface Configuration

    This option is used to turn the onboard Ethernet Disabled Disables the onboard Ethernet controller (ETH1) controller on or off. Enabled Enables the onboard Ethernet controller Table 191: GM45 Advanced - I/O interface configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 233: Clock Configuration

    Disabled Disables this function ference. Table 192: GM45 Advanced - Clock configuration - Configuration options 1.4.9 IDE configuration Figure 127: GM45 Advanced IDE Configuration Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 234 These settings are only possible if Configure SATA port 0/1 is set to RAID or AHCI. These settings are only possible if SATA port 2/3 (opt. PATA port) is set to Enhanced. 1.4.9.1 Primary IDE master Figure 128: GM45 Primary IDE Master Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 235 Auto Automatically detects the drive and configures the necessary values CD/DVD CD/DVD drive ARMD ARMD drive (zip drive) Table 195: GM45 Advanced - Secondary IDE master - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 236 This option enables IDE logical block addressing / Disabled Disables this function large mode. Auto Automatically enables this function if supported by the system Table 196: GM45 Advanced - Third IDE master - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 237 Automatically enables this function if supported per request is read from the configuration sector by the system of the hard drive. Table 197: GM45 Advanced - Fourth IDE master - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 238: Usb Configuration

    Allows BIOS Setup to be opened during POST (Power On Self Test) regardless of the Legacy using a USB keyboard USB support setting. Table 198: GM45 Advanced - USB configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 239 This option should only be used if ab- solutely necessary; otherwise, it would unnecessarily extend the boot proce- dure by the configured time. Table 198: GM45 Advanced - USB configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 240: Keyboard/Mouse Configuration

    Enables the numeric keypad Typematic rate Configures the key repeat function Slow Slow key repeat Fast Fast key repeat Table 199: GM45 Advanced - Keyboard/Mouse configuration - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 241: Cpu Board Monitor

    +12Vin Displays the current voltage of the 12 volt supply None VRTC Displays the battery voltage in volts None Table 200: GM45 Advanced - CPU board monitor - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 242: Baseboard/Panel Features

    ID) and can only be changed using the "B&R Control Center" includ- ed with the ADI driver. Table 201: GM45 Advanced - Baseboard/Panel features - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 243 Displays the fan speed for the selected panel None Keys/LEDs Displays the available keys and LEDs on the se- None lected panel Table 202: GM45 Advanced - Panel control - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 244 Case 3 Displays the speed of housing fan 3 None Case 4 Displays the speed of housing fan 4 None Table 203: GM45 Advanced - Baseboard monitor - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 245 Displays the base I/O address of the hardware 278, 378, 3BC Assigns the base I/O address for the parallel security interface port Table 204: GM45 Advanced - Legacy devices - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 246: Boot

    Information: It is only possible to use either "Device based" or "Type based". Using both to- gether is not permitted. Table 205: GM45 Boot menu - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 247: Security

    System remains off lowing power loss Turn on System powered on Last state Enables the previous state Table 205: GM45 Boot menu - Configuration options 1.6 Security Figure 140: GM45 Security Menü Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 248: Hard Disk Security User Password

    The user password allows the user to edit only certain BIOS settings. Table 207: GM45 Security - Hard disk security user password Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 249: Hard Disk Security Master Password

    Table 208: GM45 Security - Hard disk security master password 1.7 Power Figure 143: GM45 Power Menü Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 250 Disables this function Power button mode This function determines what the power button On/Off Switches the system on/off does. Suspend Suppresses this function Table 209: GM45 Power menu - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 251: Exit

    This option loads the CMOS default values de- OK / Cancel fined by the DIP switch settings. These values are loaded for all BIOS settings. Table 210: GM45 Exit menu - Configuration options Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 252: Bios Default Settings

    Allocate IRQ to PCI VGA Allocate IRQ to SMBUS HC Allocate IRQ to SMBUS PCIEX2 PCI IRQ resource exclusion Table 214: GM45 Advanced - PCI configuration - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 253 SDVO DVI SDVO DVI SDVO DVI SDVO/DVI hot plugging support Enabled Enabled Enabled Display mode persistence Enabled Enabled Enabled Table 216: GM45 Advanced - Graphics configuration - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 254 32Bit data transfer Enabled Enabled Enabled Third IDE master Type Auto Auto Auto LBA/Large mode Auto Auto Auto Table 221: GM45 Advanced - IDE configuration - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 255 Board ETH2 Board power Power supply Slide-in drive 1 Slide-in drive 2 ETH2 controller Case 1 Case 2 Table 225: GM45 Advanced - Baseboard/Panel features - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 256: Boot

    Suspend Hard disk power down mode Suspend Suspend Suspend Keyboard & PS/2 mouse MONITOR MONITOR MONITOR FDC/LPT/COM ports MONITOR MONITOR MONITOR Table 228: GM45 Power - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 257 Disabled Disabled Resume on PME# Disabled Disabled Disabled Resume on RTC alarm Disabled Disabled Disabled Power button mode On/Off On/Off On/Off Table 228: GM45 Power - Overview of profile settings Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 258: Bios Error Signals (Beep Codes)

    11x short Cache error / external cache bad: Defective L2 cache on the main- Send the industrial PC to B&R for testing. board Table 229: GM45 BIOS - POST messages Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 259: Allocation Of Resources

    The BIOS assigns the PCI and PCI Express bus I/O resources from FFF0h downward. Devices that are not compatible with PnP/PCI/PCI Express cannot use the I/O resources in this range. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 260: Interrupt Assignments In Pic Mode

    If the SATA configuration in BIOS is set to Enhanced mode for all SARA ports, IRQs 14 and 15 are enabled for the system and the SATA ports use other IRQs. ● ... Default setting ○ ... Optional setting Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 261: Interrupt Assignments In Apic Mode

    PIRQ F: PCI Bus INTA PIRQ G: PCI Bus INTB PIRQ H: PCI Bus INTC, UHCI Host Controller 0, EHCI Host Controller 0 ● ... Default setting ○ ... Optional setting Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 262 PCI 3 PCI 2 PCI 1 5PC810.BX05-01 PCIe 4 PCIe 3 PCIe 2 PCI 2 PCI 1 Figure 145: PCI and PCIe routing with enabled APIC for GM45 CPU boards (bus units 5PC810.BX0x-0x) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 263 Intel 82573L and Intel 82567 are shifted back by 1. PCI to PCI bridge. (see block diagram for 5PC810.BX05-02 bus) Figure 146: PCI and PCIe routing with the enabled 5PC810.BX05-02 APIC GM45 CPU board (bus unit 5PC810.BX05-02) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 264: Upgrade Information

    This information can be found on the following BIOS Setup screen: • After switching on the APC810, BIOS Setup can be accessed by pressing <Del>. • From the BIOS main menu "Advanced", select "Baseboard/Panel features" and then "Panel control". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 265: Procedure With Ms-Dos

    5. The following boot menu will be shown after startup: 1. Upgrade AMI BIOS for BM45 (5PC800.BM45-00, -01) 2. Exit Item 1: BIOS is automatically upgraded (default after 5 seconds). Item 2: Returns to the shell (MS-DOS) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 266 6. The system must be rebooted after a successful upgrade. 7. Reboot and press <Del> to enter BIOS Setup and load the setup defaults, then select "Save changes and exit". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 267: Firmware Upgrade

    Opens Submenu 1 for upgrading the SDLR controller on the monitor/panel interface 3.1 Upgrade SDLR on AP 0 (AP800/AP900) Automatically updates the SDLR controller on the Automation Panel 0 interface Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 268 5.3 Return to main menu Returns to the main menu Item 6: Returns to the shell (MS-DOS) Information: The system must be powered off and back on again after a successful upgrade. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 269: Possible Upgrade Problems And Software Dependencies (For V1.00)

    • The "Legacy mouse support" and "Keyboard controller reset" functions are only provided starting with the MTCX PX32 V00.12 and MTCX FPGA V00.09 combination (included on APC810 MTCX upgrade disk V00.05). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 270: Creating An Ms-Dos Boot Diskette In Windows Xp

    In Windows Explorer, go to the "Tools" menu, select "Folder options" and open the "View" tab. Then deselect the option "Hide protected operating system files (Recommended)" (enabled by default) and enable the option "Show hidden files and folders". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 271 Figure 152: Creating a bootable diskette in Windows XP - Step 4 Figure 153: Creating a bootable diskette in Windows XP - Step 5 Now all files (selected) except Command.com, IO.sys and MSDOS.sys can be deleted. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 272: Creating A Bootable Usb Flash Drive For B&R Upgrade Files

    Information about creating an MS-DOS boot diskette can be found in section see "Creating an MS-DOS boot diskette in Windows XP" on page 270. The files from the diskette are then copied to the hard drive. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 273: Creating A Bootable Compactflash Card For B&R Upgrade Files

    Windows XP" on page 270. The files from the diskette are then copied to the hard drive. 2.6 Upgrade problems Potential upgrade problems are listed in the Readme.txt files on the upgrade disks. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 274: Microsoft Dos

    1024 x 768 1280 x 1024 ✓ ✓ ✓ ✓ ✓ ✓ 1600 x 1200 ✓ ✓ ✓ 1920 x 1440 Table 236: Tested resolutions and color depths for RGB signals Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 275: Windows Xp Professional

    APC620 945GME SP2c German ≤2.1 GB 128 MB APC810 GM45 APC820 PPC700 PPC725 PPC800 5SWWXP.0500-ENG Professional APC620 945GME SP2c English ≤2.1 GB 128 MB APC810 GM45 APC820 PPC700 PPC725 PPC800 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 276: Installation

    Press "Enter" and select the driver. 6. Follow the installation instructions. 7. The installer will copy the files to the Windows XP Professional folder and restart the Automation PC 810. Information: • Not all USB FDD drives are supported by the Windows XP installer (see Microsoft KB 916196).
  • Page 277: Drivers

    Current drivers for all approved operating systems are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 278: Windows 7

    GM45 APC810 QM77/HM76 APC910 NM10 APC2100 US15W PPC800 Bay Trail PPC900 PPC2100 PP500 5SWWI7.0200-GER Professional APC810 945GME Intel® 64-bit German 20 GB 2 GB APC910 Core™2 Duo PPC800 GM45 QM77/HM76 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 279: Installation

    3. Follow the installation steps until a page appears asking "Where do you want to install Windows?". 4. Plug the USB flash drive with the RAID drivers into an available USB port. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 280: Special Considerations, Limitations

    Current drivers for all approved operating systems are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 281: Windows Embedded Standard 2009

    Windows Firewall MSN Explorer Outlook Express ✓ Administrative Tools ✓ Remote Desktop Remote Assistance .NET Framework ASP.NET ✓ Local network bridge Table 240: Device functions in Windows Embedded Standard 2009 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 282: Installation

    In accordance with Microsoft requirements, Windows Embedded Standard 2009 requires SVGA resolution (800 x 600) or higher in order to allow unimpeded operation of the Windows user interface (including system dialog boxes, etc.). A lower resolution can be selected for applications. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 283: Windows Embedded Standard 7

    ✓ File-Based Write Filter (FBWF) ✓ ✓ Administrator accounts User accounts Configurable Configurable Table 242: Device functions in Windows Embedded Standard 7 64-bit versions are not supported by all systems. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 284: Installation

    In accordance with Microsoft requirements, Windows Embedded Standard 7 requires XGA resolution (1024 x 768) or higher in order to allow unimpeded operation of the Windows user interface (including system dialog boxes and apps, etc.). A lower resolution can be selected for applications. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 285: Automation Runtime

    Table 243: 0TG1000.01, 1TG4600.10-5, 1TG4601.06-5 - Order data 8.3 Automation Runtime Windows (ARwin) System requirements In order to run Automation Runtime Windows on an Automation PC 810, the following software versions (or higher) are required: • ARwin upgrade AR 2.xx •...
  • Page 286: Automation Runtime Embedded (Aremb)

    Software • Automation Runtime 8.4 Automation Runtime Embedded (ARemb) System requirements In order to run Automation Runtime Embedded on an Automation PC 810, the following software versions (or higher) are required: • ARemb upgrade AR A4.00 • Automation Studio V3.0.90 •...
  • Page 287: R Automation Device Interface (Adi) - Control Center

    • Updating and backing up BIOS and firmware • Creating reports about the current system (support assistance) • Setting the SDL equalizer value when adjusting SDL cables • Changing the user serial ID Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 288: Installation

    If a more current ADI driver version exists (see the Downloads section of the B&R website), it can be installed later. It is important that Enhanced Write Filter (EWF) is disabled for this. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 289: Sdl Equalizer Settings

    The optimal value for the cable length is defined by selecting "Use automatic setting". The equalizer value can only be changed if the function is supported by Automation Panel 900 (Panel firmware version 1.04 or higher). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 290: Ups Configuration

    Administrator rights are required in order to change the energy options or display the UPS status. 9.4.2 Displaying UPS default values 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 291: Changing Ups Battery Settings

    1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under Battery settings, click on Edit. This opens the "Open" dialog box. 4. Select and open the file containing the battery settings. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 292: Updating Ups Battery Settings

    • The UPS cannot be operated while the battery settings are being updated. • If the transfer is aborted, then the procedure must be repeated until the battery settings have been updated successfully. Otherwise, battery operation will no longer be possible. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 293: Saving Ups Battery Settings

    • The UPS is automatically restarted after the UPS settings have been changed. This can cause a brief disruption in communication with the UPS. • Administrator rights are required in order to change the energy options or display the UPS status. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 294: Changing Additional Ups Settings

    9.4.7 Changing additional UPS settings 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under UPS settings, click on Advanced. This opens the following window: Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 295 Regardless of these options, all changes to the UPS status are logged in the Windows event log (under "Application"). The Windows Messenger service is supported starting with B&R Windows Embedded version 2.20 and higher. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 296: Procedure Following Power Failure

    If power returns during the switch-off time, then the shutdown procedure is aborted. If power returns during the shutdown process, then the shutdown timer will run until the B&R Industrial PC enters standby mode, at which point the system will be rebooted. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 297: R Automation Device Interface (Adi) Development Kit

    • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 298 A detailed description of how to use ADI functions can be found in the help system. The B&R Automation Device Interface (ADI) development kit is available at no cost in the Downloads section of the B&R website (www.br-automation.com). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 299: R Automation Device Interface (Adi) .Net Sdk

    • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 • Power Panel 100/200 • Power Panel 300/400 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 300 A detailed description of how to use ADI functions can be found in the help system. The ADI .NET SDK is available in the Downloads section of the B&R website (www.br-automation.com). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 301: R Key Editor

    • Automation PC 511 • Automation PC 620 • Automation PC 810 • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Automation Panel 800 • Automation Panel 830 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 302 Editor is available at no cost in the Downloads section of the B&R website (www.br-automation.com). It can also be found on the B&R HMI Drivers & Utilities DVD (model number 5SWHMI.0000-00). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 303: Chapter 5 Standards And Certifications

    EN 61131-2:2007 Programmable logic controllers - Part 2: Equipment requirements and tests EN 60204-1:2006 + Safety of machinery - Electrical equipment of machines - Part 1: General require- A1:2009 ments Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 304: Certifications

    Products with this mark have been certified by an accredited certification body and have been approved for use in potentially explosive environments. II 3D Ex tc IIIA T85°C Dc IP20 Tamb: 0°C to 55°C FTZU 11 E 0001U Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 305: Requirements For Use In Potentially Explosive Environments

    Mounting and installation Automation PC 810 systems must be installed according to the guidelines in the user's manual. In order to guar- antee sufficient air circulation, the specified amount of space around the device must be provided. The maximum ambient temperature is 50ºC.
  • Page 306: Gost-R

    Standards and certifications • Certifications 2.3 GOST-R Products with this mark have been certified by an accredited testing laboratory and have been approved for import to the Russian Federation (based on CE compliance). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 307: Chapter 6 Accessories

    General information Storage time Max. 3 years at 30°C Certification cULus Electrical characteristics Capacity 950 mAh Self-discharging <1% per year (at 23°C) Voltage range Table 245: 0AC201.91, 4A0006.00-000 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 308 0AC201.91 4A0006.00-000 Environmental conditions Temperature Storage -20 to 60°C Relative humidity Operation 0 to 95% Storage 0 to 95% Transport 0 to 95% Table 245: 0AC201.91, 4A0006.00-000 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 309: Power Connectors

    Yes, although applies only if all components installed within the complete system have this certification. Cage clamp terminal blocks cannot be used side-by-side. The limit data for each I/O module must be taken into consideration. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 310: Replacement Fan

    APC810 replacement fan filter for 5PC810.SX02-00; 5 pcs. 5AC801.FA03-00 APC810 replacement fan filter for 5PC810.SX03-00; 5 pcs. 5AC801.FA05-00 APC810 replacement fan filter for 5PC810.SX05-00; 5 pcs. Table 248: 5AC801.FA01-00, 5AC801.FA02-00, 5AC801.FA03-00, 5AC801.FA05-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 311: Dvi/Monitor Adapter

    Model number Short description Figure Miscellaneous 5AC900.1000-00 DVI (male connector) to CRT (female connector) adapter. For connecting a standard monitor to a DVI-I interface. Table 249: 5AC900.1000-00 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 312: Compactflash Cards

    Critical performance and calibration data is monitored and stored in order to help predict the probability of errors. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 313: Maximum Reliability

    Accessories • CompactFlash cards 5.2.5 Maximum reliability CompactFlash cards used by B&R use SLC flash blocks and static wear leveling together with a powerful ECC algorithm to provide maximum reliability. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 314: 5Cfcrd.xxxx-06

    5CFCRD.016G-06 CompactFlash 16 GB B&R (SLC) ≤ Rev. D0 5CFCRD.032G-06 CompactFlash 32 GB B&R (SLC) ≤ Rev. C0 Table 251: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 315: Technical Data

    ≥ V3.0.2.3014) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V3.0.0.3020) B&R Embedded OS Installer ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.20 ≥V3.21 Table 252: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 316 28 MB/s 28 MB/s Maximum 18 MB/s 18 MB/s 18 MB/s 17 MB/s 17 MB/s 30 MB/s 30 MB/s Table 253: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 317 Yes, although applies only if all components installed within the complete system have this certification Endurance of B&R CFs (with linear written block size ≥128 kB). Not supported by the B&R Embedded OS Installer. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 318: Temperature/Humidity Diagram

    1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 167: Type I CompactFlash card - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 319: Benchmark

    Transfer size [kB] Figure 168: ATTO Disk Benchmark v2.34 read comparison - 5CFCRD.xxxx-04 and 5CFCRD.xxxx-06 Transfer size [kB] Figure 169: ATTO Disk Benchmark v2.34 write comparison - 5CFCRD.xxxx-04 and 5CFCRD.xxxx-06 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 320: 5Cfcrd.xxxx-04

    Maximum 37 MB/s 37 MB/s 37 MB/s 34 MB/s 28 MB/s 37 MB/s (260X) (260X) (260X) (226X) (186X) (247X) Table 255: 5CFCRD.0512-04, 5CFCRD.1024-04, 5CFCRD.2048-04, 5CFCRD.4096-04, 5CFCRD.8192-04, 5CFCRD.016G-04 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 321 Speed specification with 1X = 150 Kb/s. All specifications refer to Samsung flash chips, CompactFlash cards in UDMA mode 4 and 30 ns cycle time in True IDE mode with sequential write/read test. Yes, although applies only if all components installed within the complete system have this certification Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 322: Temperature/Humidity Diagram

    1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 171: Type I CompactFlash card - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 323: Benchmark

    Transfer size [kB] Figure 172: ATTO Disk Benchmark v2.34 read comparison - 5CFCRD.xxxx-03 and 5CFCRD.xxxx-04 Transfer size [kB] Figure 173: ATTO Disk Benchmark v2.34 write comparison - 5CFCRD.xxxx-03 and 5CFCRD.xxxx-04 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 324: 5Cfcrd.xxxx-03

    8 GB Data retention 10 years Data reliability <1 unrecoverable error in 10 bit read accesses Lifetime monitoring Table 257: 5CFCRD.0064-03, 5CFCRD.0128-03, 5CFCRD.0256-03, 5CFCRD.0512-03, 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 325 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Yes, although applies only if all components installed within the complete system have this certification Not supported by the B&R Embedded OS Installer. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 326: Temperature/Humidity Diagram

    1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 175: Type I CompactFlash card - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 327: Known Problems/Issues

    The problem described can occur because the startup time for the CompactFlash cards fluctuates due to the different components being used. Depending on the CompactFlash card being used, this error might never, sometimes or always occur. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 328: Usb Media Drive

    The following characteristics, features and limit values only apply to this individual component and can deviate from those specified for the complete system. For the complete system in which this individual component is used, refer to the data given specifically for that device. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 329 Front: IP65 (only with optional front cover), back: IP20 Environmental conditions Temperature Operation 5 to 45°C Storage -20 to 60°C Transport -40 to 60°C Table 259: 5MD900.USB2-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 330: Dimensions

    Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). 6.1.5 Dimensions Figure 177: 5MD900.USB2-01 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 331: Dimensions With

    Because of limits to the mounting orientation with the components used (floppy, DVD-CDRW drive), the USB media drive is only permitted to be mounted and operated as shown in the following figure. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 332 Accessories • USB media drive Less than 20° Less than 20° Less than 20° Less than 20° Figure 180: 5MD900.USB2-01 - Mounting orientation Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 333: 5Md900.Usb2-02

    Type A front Type B back Transfer rate Low speed (1.5 Mbit/s), full speed (12 Mbit/s), high speed (480 Mbit/s) Current load Max. 500 mA Table 262: 5MD900.USB2-02 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 334 Table 262: 5MD900.USB2-02 - Technical data Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 335: Dimensions

    Accessories • USB media drive 6.2.5 Dimensions Figure 182: 5MD900.USB2-02 - Dimensions 6.2.6 Dimensions with front cover Figure 183: USB media drive with front cover - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 336: Cutout Installation

    The USB media drive can be operated as a desktop device (rubber feet) or as a rack-mounted device (2 mounting rail brackets included). 6.2.9.1 Mounting orientation Less than 20° Less than 20° Less than 20° Less than 20° Figure 185: 5MD900.USB2-02 - Mounting orientation Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 337: 5A5003.03

    Figure 186: 5A5003.03 - Dimensions 6.3.5 Contents of delivery Quantity Component Front cover 5A5003.03 for the USB media drive M3 locknut Cover retaining clip Table 266: 5A5003.03 - Contents of delivery Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 338: Installation

    Outer contour (front cover) Outer contour (media device) 67.5 Cutout Cutout size 183 ±0.5 mm x 55 ±0.5 mm 12.5 189.5 Figure 188: USB media drive with front cover - Installation cutout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 339: Usb Flash Drives

    Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Power consumption 650 µA sleep mode, 150 mA read/write Table 268: 5MMUSB.2048-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 340: Temperature/Humidity Diagram

    52.2 mm Height 7.9 mm Table 268: 5MMUSB.2048-00 - Technical data Indicates data being transferred (sending and receiving). 7.1.4 Temperature/Humidity diagram Operation Temperature [°C] Figure 189: 5MMUSB.2048-00 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 341: 5Mmusb.xxxx-01

    Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Current consumption Max. 500 μA sleep mode, max. 120 mA read/write Table 270: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 342: Temperature/Humidity Diagram

    8.35 mm Table 270: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Indicates data being transferred (sending and receiving). 7.2.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 190: 5MMUSB.xxxx-01 - Temperature/Humidity diagram Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 343: Hmi Drivers & Utilities Dvd

    • Automation PC 620 / Panel PC 700 CPU board 945GME N270 BIOS • Automation PC 680 • Automation PC 810 / Automation PC 820 / Panel PC 800 B945GME BIOS • Automation PC 810 / Panel PC 800 945GME N270 CPU board BIOS •...
  • Page 344 • Windows Embedded Standard 2009 • Windows Embedded Standard 7 • Thin client • Windows NT Embedded • Windows XP Embedded • VNC viewer MCAD templates for • Industrial PCs Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 345 • Acrobat Reader 5.0.5 (freeware in German, English and French) • Power Archiver 6.0 (freeware in German, English and French) • Internet Explorer 5.0 (German and English) • Internet Explorer 6.0 (German and English) Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 346: Uninterruptible Power Supply

    • Add-on UPS module 5AC600.UPSI-00 • Battery unit 5AC600.UPSB-00 • UPS connection cable 0.5 m (5CAUPS.0005-00) or 3 m (5CAUPS.0030-00) • Configuration of the B&R UPS in the ADI Control Center Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 347: 5Ac600.Upsi-00

    Yes, although applies only if all components installed within the complete system have this certification 9.3.4 Installation This module is installed using the materials included in delivery. For more information regarding installation, see chapter 7 "Maintenance and service". Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 348 Connection cables Spacer bolt (14 mm) Mounting bracket Spacer bolt (16 mm) UPS insulation Spacer sleeve (2 mm) Torx screws (T10) Figure 192: 5AC600.UPSI-00 Add-on UPS module - Installation materials Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 349: 5Ac600.Upsb-00

    -65 to 80°C Relative humidity Operation 5 to 95%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Altitude Operation Max. 3000 m Table 275: 5AC600.UPSB-00, 5AC600.UPSB-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 350: Service Life

    50% reduction in service life expectancy when temperature increased by 8°C 33°C Ambient temperature [°C] 9.4.5 Deep discharge cycles 1000000 100000 10000 1000 Discharge depth [%] Figure 193: Deep discharge cycles Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 351: Dimensions

    170.5 141.9 38.9 126.5 Figure 195: 5PC600.UPSB-00 - Drilling template 9.4.8 Installation instructions Due to the unique construction of these batteries, they can be stored and operated in any position. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 352: 5Caups.00Xx-00

    5x wire cross section Weight Approx. 100 g Approx. 470 g Table 277: 5CAUPS.0005-00, 5CAUPS.0030-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 353: 5Ac600.Upsf-00

    These 25 A fuses are replacement parts for the 5AC600.UPSB-00 battery unit (beginning with revision E0) as well as the 5AC600.UPSF-00 fuse kit. 9.7.2 Order data Model number Short description Figure Uninterruptible power supplies 5AC600.UPSF-01 UPS fuse, 5 pcs. Table 279: 5AC600.UPSF-01 - Order data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 354: Line Filter

    Length 94 mm Depth 32.15 mm Weight 205 g Table 281: 5AC804.MFLT-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 355: Dimensions

    • Keep the lines as short as possible (supply voltage - line filter - end device). • The line filter must be installed on an unpainted, oil-free metallic surface. Line filter End device Figure 198: Connection example Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 356: Pci Plug-In Cards

    Product ID 5ACPCI.ETH1-01 General information B&R ID code 0xA58A Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 283: 5ACPCI.ETH1-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 357: Driver Support

    (Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 358: Dimensions

    Accessories • PCI plug-in cards 11.1.5 Dimensions 42.6 106.3 121.7 Figure 200: 5ACPCI.ETH1-01 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 359: 5Acpci.eth3-01

    Product ID 5ACPCI.ETH3-01 General information B&R ID code 0xA58B Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 286: 5ACPCI.ETH3-01 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 360: Driver Support

    (Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 361: Dimensions

    Accessories • PCI plug-in cards 11.2.5 Dimensions 42.6 106.3 121.7 Figure 202: 5ACPCI.ETH3-01 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 362: Cables

    Approx. 260 g Approx. 460 g Approx. 790 g Table 289: 5CADVI.0018-00, 5CADVI.0050-00, 5CADVI.0100-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 363 Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 203: Flex radius specifications 12.1.1.5 Dimensions 28.5 25±5 Length Figure 204: 5CADVI.0xxx-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 364 B&R are guaranteed to function properly, however. DVI-D (24+1), male DVI-D (24+1), male Pinout DVI-D (24+1), male DVI-D (24+1), male Cable shield Cable shield Figure 205: 5CADVI.0xxx-00 - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 365: Sdl Cables

    Max. 11.5 mm Flex radius ≥5x cable diameter (male connector - ferrite bead and ferrite bead - ferrite bead) Table 291: 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0100-00, 5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 366 Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 206: Flex radius specifications 12.2.1.5 Dimensions 35±5 28.5 Length Figure 207: 5CASDL.0xxx-00- Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 367 B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 208: 5CASDL.0xxx-00 - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 368: Sdl Cables With 45° Male Connector

    Approx. 2800 g Approx. 2860 g Table 293: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01, 5CASDL.0150-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 369 Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 209: Flex radius specifications 12.3.1.5 Dimensions 35±5 28.5 Length Figure 210: 5CASDL.0xxx-01 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 370 B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 211: 5CASDL.0xxx-01 - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 371: Sdl Flex Cables

    Flame-retardant In accordance with UL758 (cable vertical flame test) Oil and hydrolysis resistance In accordance with VDE 0282-10 Table 295: 5CASDL.0018-03, 5CASDL.0050-03, 5CASDL.0100-03, 5CASDL.0150-03, 5CASDL.0200-03, 5CASDL.0250-03, 5CASDL.0300-03 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 372 Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 212: Flex radius specifications 12.4.1.5 Dimensions 36.5 ±10 37.5 ±2.5 Length Figure 213: 5CASDL.0xxx-03 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 373 SDL- TMDS data 2/SDL shielding TMDS data 2/SDL shielding TMDS data 2+ TMDS data 2+ TMDS data 2- TMDS data 2- Cable shield Cable shield Figure 214: 5CASDL.0xxx-03 - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 374: Sdl Flex Cables With Extender

    In accordance with VDE 0282-10 Environmental conditions Temperature Storage -20 to 60°C Fixed installation -20 to 60°C Flexible installation -5 to 60°C Table 298: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 375 Male connector - Ferrite bead Ferrite bead - Extender Ferrite bead Extender Figure 215: Flex radius specification with extender 12.5.1.5 Dimensions 36.5 ±10 37.5 ±2.5 Length Figure 216: 5CASDL.0xx0-13 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 376 B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 217: 5CASDL.0xx0-13 - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 377 The proper signal direction is indicated on the extender. B&R Industrial PC Figure 218: Example of the signal direction for an SDL flex cable with extender Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 378: Usb Cables

    If a field-assembled cable is used, B&R cannot guarantee that it will function properly. All cables pro- vided by B&R are guaranteed to function properly, however. Pinout USB Type A, male USB Type B, male Jacket Jacket Figure 219: 5CAUSB.00xx-00 USB cables - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 379: Rs232 Cables

    Length 1.8 m ±50 mm 5 m ±80 mm 10 m ±100 mm Diameter Max. 5 mm Flex radius Min. 70 mm Table 302: 9A0014.02, 9A0014.05, 9A0014.10 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 380 B&R are guaranteed to function properly, however. 9-pin male DSUB 9-pin female DSUB Pinout 9-pin male DSUB 9-pin female DSUB Jacket Jacket Figure 220: 9A0014.xx RS232 cables - Pinout Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 381: Internal Supply Cable

    Connector Type 1x 4-pin male disk drive power connector, 1x 4-pin female connector housing Mechanical characteristics Dimensions Length 100 mm ±5 mm Flexibility Flexible Table 304: 5CAMSC.0001-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 382: Hdd Replacement Disk Tray

    Table 305: 5AC801.FRAM-00 - Order data 13.1.3 Technical data Product ID 5AC801.FRAM-00 General information Certification GOST-R Mechanical characteristics Dimensions Width 106 mm Height 101 mm Depth 18 mm Table 306: 5AC801.FRAM-00 - Technical data Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 383: Dimensions

    Accessories • HDD replacement disk tray 13.1.4 Dimensions +0.2 - 0.2 Figure 222: 5AC801.FRAM-00 - Dimensions Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 384: Chapter 7 Maintenance And Service

    • Touch the housing or ground connection in order to discharge any electrostatic charge from your body. • Remove the cover from the battery compartment and carefully pull out the battery using the removal strip. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 385 • Reconnect the power supply to the B&R Industrial PC (plug in the power cable). • Reset the date and time in BIOS. Warning! Lithium batteries are considered hazardous waste. Used batteries should be disposed of in accordance with applicable local regulations. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 386: Replacing A Compactflash Card

    The CompactFlash card can be replaced quickly and easily by pressing the ejector (see image) with a pointed object such as a pen. Ejector CompactFlash Figure 226: CompactFlash + ejector Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 387: Installing And Replacing Slide-In Compact Drives

    Loosening the 2 quick release screws Figure 227: Loosening the quick release screws 2. Insert the compact SATA drive and tighten the quick release screws. Figure 228: Inserting the compact SATA drive Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 388: Installing And Replacing Slide-In Drives

    Loosening the 2 quick release screws Figure 229: Loosening the quick release screws 4. Insert the slide-in drive and tighten with the two ¼ turn screws. Figure 230: Installing the slide-in drive Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 389: Installing A Slide-In Compact Adapter

    4. Insert the slide-in compact adapter and tighten the two quick release screws. Figure 232: Installing the slide-in compact adapter 5. Once the adapter has been installed, the slide-in compact drive can be inserted. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 390 Maintenance and service • Installing a slide-in compact adapter Figure 233: Inserting the slide-in compact drive Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 391: Installing And Replacing Fan Kits

    Contact board Sliding contact Contact board Figure 235: Inserting and fastening the fan kit 3. Place the dust filter in the fan kit cover and secure it with the filter clasp. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 392 4. Place the fan kit cover in the housing and fasten using the Torx screws removed earlier. Information: The dust filter should be checked regularly depending on the area of use and degree of contam- ination. Installation is the same as for all APC810 devices. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 393: Installing The Ups Module

    4. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 2 Torx screws (T10) on the housing and 1 Torx screw (T10) on the mainboard (spacer bolt). Use the previously removed Torx screws from the installation material. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 394 5. Attach the connection cable (see marked female connector). Figure 241: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 242: Connector locking mechanism 6. Attach the side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 395: 2- And 3-Slot Apc810

    5. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 2 Torx screws (T10) on the housing and 1 Torx screw (T10) on the mainboard (spacer bolt). Use the previously removed Torx screws from the installation material. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 396 6. Attach the connection cable (see marked female connector). Figure 247: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 248: Connector locking mechanism 7. Attach the side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 397: 5-Slot Apc810

    5. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 2 Torx screws (T10) on the housing and 1 Torx screw (T10) on the mainboard (spacer bolt). Use the previously removed Torx screws from the installation material. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 398 6. Attach the connection cable (see the marked female connector). Figure 253: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 254: Connector locking mechanism 7. Attach the side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 399: Installation With Installed Add-On Interface Module

    4. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 3 Torx screws (T10). Use the previously removed Torx screws and a Torx screw from the installation material. Figure 257: Installing the UPS module 5. Attach the connection cable (see marked female connector). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 400 Figure 258: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 259: Connector locking mechanism 6. Attach the cover plate and side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 401: 2- And 3-Slot Apc810

    5. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 3 Torx screws (T10). Use the previously removed Torx screws and a Torx screw from the installation material. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 402 Figure 264: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 265: Connector locking mechanism 7. Attach the cover plate and side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 403: 5-Slot Apc810

    5. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 3 Torx screws (T10). Use the previously removed Torx screws and a Torx screw from the installation material. Figure 269: Installing the UPS module 6. Attach the connection cable (see marked female connector). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 404 Figure 270: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 271: Connector locking mechanism 7. Attach the cover plate and side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 405: Installing The Ups Fuse Kit On The Battery Unit

    Figure 272: Removing the cover for the battery unit 3. To install the fuse, the red cable must be disconnected from the battery circuit board. Figure 273: Disconnecting the cable Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 406 6. The cover for the battery unit can now be reattached. Insert the clips on the cover into the notch on the battery unit and tighten down the cover with the Torx screws removed previously. 7. Reconnect the 5AC600.UPSB-00 battery unit to the B&R Industrial PC. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 407: Installing The Side Cover

    9.1 1-slot APC810 1. Disconnect the power supply to the Automation PC 810. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3. Open the orange front cover. The Combi-Torx screws (T10) behind the cover that are marked in the image must then be removed.
  • Page 408: 5-Slot Apc810

    Maintenance and service • Installing the side cover 9.3 5-slot APC810 1. Disconnect the power supply to the Automation PC 810. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3. Open the orange front cover. The Combi-Torx screws (T10) behind the cover that are marked in the image must then be removed.
  • Page 409: Ap Link Installation

    Torx screw from the installation material. AP Link ready relay AP Link SDL transmitter Figure 280: Installing the AP Link module 5. Attach the cover plate and side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 410: Replacing A Pci Sata Raid Hard Disk In A Raid 1 Set

    7. Insert the new hard disk carefully into the connector (Replacing the hard disk - right image), being careful to only touch it on the front, not on the top. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 411 11. A rebuild can be performed immediately in SATA RAID BIOS or once the PC has booted - see "Rebuild mirrored set" on page 214. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 412: Installing The Hdd Replacement Disk Tray

    4. Affix to the inside of the side cover by lightly bending the hooks with a suitable tool (e.g. universal pliers). Figure 284: Installing the replacement disk tray in the APC810 5. Attach the side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 413: Installing The Ready Relay /2 In The Add-On Ups Slot

    (T6) on the mainboard (spacer bolt). Figure 287: Installing the ready relay 5. Attach the connection cable. Information: When connecting the internal supply voltage cable, make sure that the connector locks into place. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 414 Maintenance and service • Installing the ready relay /2 in the add-on UPS slot Figure 288: Attaching the connection cable 6. Attach the side cover. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 415: Maintenance Controller Extended (Mtcx)

    29), which directly determines how the fans are controlled. The speed depends on the measured temperature. Limit values may depend on the MTCX firmware version being used. Available in the Downloads section of the B&R website (www.br-automation.com). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 416 For example, slide-in 1/2: 44°C + 16°C = 60°C --> Maximum fan speed The fans will only be shut off again if the evaluation temperature is more than 6°C below the switch-on temperature for a period of 4 hours (=overshoot time). Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 417: Connecting An External Device To The Mainboard

    Power 4-pin connector, male +12 VDC Max. 10 watts Max. 5 watts +5 VDC Table 310: Connector on the mainboard - Pinout Connections are protected with a 1 A multi-fuse. Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 418 5AC801.HDDS-00 - Temperature humidity diagram............127 Figure 54: 5AC801.DVDS-00 - Temperature humidity diagram............129 Figure 55: 5AC801.DVRS-00 - Temperature humidity diagram............132 Figure 56: PCI SATA RAID controller....................133 Figure 57: 5ACPCI.RAIC-03 - Temperature humidity diagram.............135 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 419 RAID Configuration Utility - Delete RAID set..............213 Figure 112: RAID Configuration Utility - Rebuild mirrored set..............214 Figure 113: RAID Configuration Utility - Resolve conflicts..............214 Figure 114: RAID Configuration Utility - Low level format..............215 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 420 Figure 167: 5CFCRD.xxxx-06 - Temperature/Humidity diagram for CompactFlash cards.....318 Figure 168: Type I CompactFlash card - Dimensions................318 Figure 169: ATTO Disk Benchmark v2.34 read comparison - 5CFCRD.xxxx-04 and 5CFCRD.xxxx-06. 319 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 421 9A0014.xx RS232 cables - Pinout ..................380 Figure 222: 5AC801.FRAM-00 - HDD replacement disk tray..............382 Figure 223: 5AC801.FRAM-00 - Dimensions..................383 Figure 224: Removing the battery......................385 Figure 225: Battery handling........................385 Figure 226: Battery polarity........................385 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 422 Removing the AP Link module cover..................409 Figure 281: Installing the AP Link module....................409 Figure 282: Screw layout on the back side of the 5ACPCI.RAIC-03 SATA RAID controller....410 Figure 283: Replacing the hard disk.......................411 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 423 Screwing in the spacer bolt and spacer ring...............413 Figure 288: Installing the ready relay..................... 413 Figure 289: Attaching the connection cable................... 414 Figure 290: MTCX controller location..................... 415 Figure 291: Connector location for external devices................417 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 424 5PC800.BM45-00, 5PC800.BM45-01 - Order data..............97 Table 52: 5PC800.BM45-00, 5PC800.BM45-01 - Technical data.............. 97 Table 53: 5AC801.HS00-01 - Order data....................99 Table 54: 5AC801.HS00-01 - Technical data..................... 99 Table 55: 5MMDDR.2048-02, 5MMDDR.4096-02 - Order data..............100 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 425 Table 108: 5PC810.FA01-00 - Technical data....................160 Table 109: 5PC810.FA02-01 - Order data....................161 Table 110: 5PC810.FA02-01 - Technical data....................161 Table 111: 5PC810.FA03-00 - Order data....................163 Table 112: 5PC810.FA03-00 - Technical data....................163 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 426 Table 166: Cable lengths and resolutions for SDL transmission..............201 Table 167: Possible system unit and CPU board combinations..............202 Table 168: Link modules..........................202 Table 169: Cables for SDL configurations....................202 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 427 GM45 Advanced - CPU board monitor - Overview of profile settings........255 Table 225: GM45 Advanced - Baseboard/Panel features - Overview of profile settings......255 Table 226: GM45 Main - Overview of profile settings................256 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 428 5MMUSB.2048-00 - Order data....................339 Table 268: 5MMUSB.2048-00 - Technical data..................339 Table 269: 5MMUSB.2048-01, 5MMUSB.4096-01 - Order data..............341 Table 270: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data............341 Table 271: 5SWHMI.0000-00 - Order data....................343 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 429 Overview of required replacement SATA HDD for PCI SATA HDD RAID controller....410 Table 309: Temperature limits of the fan (MTCX PX32 ≥ V0.06)...............416 Table 310: Connector on the mainboard - Pinout..................417 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 430 5CADVI.0100-00..............................362 5CAMSC.0001-00..............................381 5CASDL.0018-00..............................365 5CASDL.0018-01..............................368 5CASDL.0018-03..............................371 5CASDL.0050-00..............................365 5CASDL.0050-01..............................368 5CASDL.0050-03..............................371 5CASDL.0100-00..............................365 5CASDL.0100-01..............................368 5CASDL.0100-03..............................371 5CASDL.0150-00..............................365 5CASDL.0150-01..............................368 5CASDL.0150-03..............................371 5CASDL.0200-00..............................365 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 431 5MMSSD.0180-00..............................156 5MMSSD.0256-00..............................158 5MMUSB.2048-00..............................339 5MMUSB.2048-01..............................341 5MMUSB.4096-01..............................341 5PC800.BM45-00..............................97 5PC800.BM45-01..............................97 5PC810.BX01-00..............................95 5PC810.BX01-01..............................95 5PC810.BX02-00..............................95 5PC810.BX02-01..............................95 5PC810.BX03-00..............................95 5PC810.BX05-00..............................95 5PC810.BX05-01..............................95 5PC810.BX05-02..............................95 5PC810.FA01-00..............................160 5PC810.FA02-01..............................161 5PC810.FA03-00..............................163 5PC810.FA05-00..............................165 5PC810.SX01-00..............................67 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 432 5SWWI7.1533-ENG............................. 283 5SWWI7.1633-ENG............................. 283 5SWWI7.1733-MUL..............................283 5SWWI7.1833-MUL..............................283 5SWWXP.0500-ENG............................275 5SWWXP.0500-GER............................275 5SWWXP.0500-MUL............................275 5SWWXP.0600-ENG............................275 5SWWXP.0600-GER............................275 5SWWXP.0600-MUL............................275 5SWWXP.0733-ENG............................281 9A0014.02................................379 9A0014.05................................379 9A0014.10................................379 9S0000.01-010..............................274 9S0000.01-020..............................274 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 433 Drilling template..............................73 APC810 with 2 card slot Drilling template..............................80 APC810 with 3 card slot Drilling template..............................87 APC810 with 5 card slot Drilling template..............................93 AP Link installation............................. 409 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 434 DVI.................................. 362 RS232................................379 SDL................................. 365 SDL flex................................371 SDL flex cables with extender........................374 SDL with 45° male connector........................368 USB................................378 Card slots................................58 CE mark................................303 Certifications............................... 304 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 435 Embedded OS Installer............................273 EMC directive..............................303 ESD..................................16 Electrical components with a housing......................16 Electrical components without a housing......................16 Individual components............................16 Packaging................................. 16 ETH1..................................53 ETH2..................................54 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 436 Installing the side cover............................. 407 Installing the UPS fuse kit..........................405 Installing the UPS module..........................393 Interfaces................................49 Interrupt assignment............................260 Key Editor................................301 LED..................................60 LED status indicators............................60 Line filter................................354 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 437 Safety guidelines..............................16 Environmental conditions..........................17 Environmentally friendly disposal........................18 Installation................................. 17 Intended use..............................16 Operation................................17 Policies and procedures........................... 16 Protection against electrostatic discharge....................... 16 Separation of materials............................ 18 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 438 Standard shutdown............................296 Updating battery settings..........................292 UPS configuration............................290 UPS configuration............................... 290 UPS fuse kit............................... 405, 405 USB cables................................. 378 USB flash drive..............................339 USB interfaces..............................55 USB media drive..............................328 Automation PC 810 with GM45 CPU Board user's manual V1.38...
  • Page 439 Index user serial ID..............................287 WES2009................................281 WES7.................................. 283 Windows 7................................278 Windows Embedded Standard 2009........................281 Windows Embedded Standard 7........................283 Windows XP Professional..........................275 Automation PC 810 with GM45 CPU Board user's manual V1.38...

Table of Contents