B&R Automation PC 3100 User Manual page 104

Hide thumbs Also See for Automation PC 3100:
Table of Contents

Advertisement

Technical data
4.7.5.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
General information
LEDs
B&R ID code
Certifications
CE
UL
Interfaces
Add-on interface slot
Quantity
Electrical properties
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Ambient conditions
1)
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical properties
Weight
1)
These values can be limited by the memory module used.
2)
Without memory module.
4.7.5.1.3.1 Status LED
Adapter card 5ACCMS01.MDT2-000 has a yellow LED status indicator on
the front panel that serves as an activity indicator.
• On: Mass storage device being accessed (write or read procedure)
• Off: Mass storage device not being accessed
104
5ACCMS01.MDT2-000
Yes, 1x activity indicator
0xFCCC
Yes
cULus E115267
Industrial control equipment
1x M.2 SSD
Depends on the memory module used
Pollution degree 2
0 to 55°C
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
Approx. 35 g
2)
Automation PC 3100 User's manual V 2.10