A.3.3 System stop error codes
A system stop error can occur due to incorrect configuration or defective hardware.
The error code is indicated by LED "S/E" blinking red. The blinking signal of the error code consists of 4 switch-on
phases with short (150 ms) or long (600 ms) duration. The error code is repeated every 2 seconds.
150
300
600
Error
Error description
RAM error
The device is defective and must be replaced.
Hardware error
The device or a system component is defective and must be replaced.
A.3.4 POWERLINK V2
By default, the POWERLINK interface is operated as a managing node (MN). In the managing node, the node
number is set to a fixed value of 240.
If the POWERLINK node is operated as a controlled node (CN), a node number from 1 to 239 can be set in the
POWERLINK configuration in Automation Studio.
244
150
300
150
300
600
300
150
300
150
300
600
2000
2000
Automation PC 3100 User's manual V 2.10
RAM error
Hardware error
All times in ms