B&R Automation PC 3100 User Manual page 84

Hide thumbs Also See for Automation PC 3100:
Table of Contents

Advertisement

Technical data
Model number
Ambient conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical properties
Weight
1)
Switching takes place automatically.
2)
For detailed information, see the temperature tables in the user's manual.
4.7.4.11.3.1 ETH - Pinout
The Ethernet interface is available in the IF option 2 slot.
Variant
Controller
Wiring
Transfer rate
Cable length
LED "Speed" (a)
Green
Orange (light)
LED "Link" (b)
Orange (light)
1)
The interfaces, etc. available on the device or module have been numbered for the purpose of clear differentiation. This numbering may deviate from the
numbering used by the respective operating system, however.
2)
Switching takes place automatically.
3)
The 10 Mbit/s transfer rate / connection is only available if LED "Link" is active at the same time.
Driver support
A special driver is necessary to operate Intel Ethernet controller I210. Drivers for approved operating systems are
available for download in the Downloads section of the B&R website (www.br-automation.com) (if required and not
already included in the operating system).
Approved operating systems:
• Windows 10
• B&R Linux
Wake-on-LAN (WoL) and PXE boot are not supported.
Information:
Necessary drivers must be downloaded from the B&R website, not from manufacturer websites.
84
Ethernet interface (ETH
RJ45, female
Intel I210
S/STP (Cat 5e)
10/100/1000 Mbit/s
Max. 100 m (min. Cat 5e)
On
100 Mbit/s
1000 Mbit/s
On
Link (a connection to an
Ethernet network exists)
5ACCIF02.CANE-000
0 to 55°C
2)
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
Approx. 100 g
)
1)
2)
Off
10 Mbit/s
3)
-
Active
Blinking (data be-
ing transferred)
Automation PC 3100 User's manual V 2.10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apc 3100

Table of Contents