Technical data
4.7.4.9.3.1 Pinout
Cable length
Pin
1
2
3
4
5
6
7
8
9
For information about LED "Power", see section
For information about the power and reset buttons, see section
4.7.4.9.3.2 Connection example
Information:
Series resistors for the LEDs are already installed on the interface option.
The LED outputs are dimensioned for a typical LED current of 3.5 mA.
80
Ready relay
Max. 2 meters
Pinout
Output LED ("Power") - Green
Output LED ("Power") - Red
GND
Input - Power button
Input - Reset button
Relay, normally open contact
Relay, normally closed contact
GND
COM relay, changeover contact
"LED status indicators" on page
GND
5
9
COM
"Power and reset buttons" on page
1
6
NC
NO
GND
DSUB, 9-pin, female
5
9
6
1
43.
42.