Environmental Properties; Temperature Specifications; Maximum Ambient Temperature For Worst-Case Operation; Minimum Ambient Temperature For Worst-Case Operation - B&R Automation PC 3100 User Manual

Hide thumbs Also See for Automation PC 3100:
Table of Contents

Advertisement

Technical data

4.5 Environmental properties

4.5.1 Temperature specifications

Because it is possible to combine different system units with a graphics option and interface option, the following
tables provide a component-dependent overview of the maximum, minimum and typical possible ambient temper-
atures resulting from these combinations.
Information:
The minimum and maximum specified ambient temperatures were determined under worst-case con-
ditions for operation. Experience has shown that higher ambient temperatures can be achieved with
typical applications in Microsoft Windows, for example. The relevant test and assessment must be
carried out individually by the user on site (reading out the temperatures in BIOS or using the ADI
Control Center, for example).
Information about worst-case conditions
• Thermal Analysis Tool (TAT V5) from Intel for simulating processor utilization (100% CPU, 100% graphics ,
100% memory)
• BurnInTest V7.1 Pro from PassMark Software for simulating 100% interface utilization using loopback
adapters (100% network)
• 4x 1 A USB load
• Maximum expansion and power consumption of the system

4.5.1.1 Maximum ambient temperature for worst-case operation

All temperature specifications in degrees Celsius
[°C] at 500 m above sea level, non-condensing.
The respective ambient temperature is derated approx.
1°C per 1000 meters starting at 500 m above sea level.
Maximum ambient temperature (accessories)
CFast cards
5ACCLI02.DPO0-000
Graphics options
5ACCLI02.SDL0-000
5ACCLI02.SD40-000
Interface options
5AC901.ISRM-000
5ACCIF02.CANE-000
5ACCIF02.FPLK-000
5ACCIF02.FPLS-000
5ACCIF02.FPSC-000
5ACCIF02.ISS0-000
5ACCIF04.FPLK-000
Mass storage options
5ACCMS01.MDT2-000
1)
1)
These values can be limited by the memory module used.

4.5.1.2 Minimum ambient temperature for worst-case operation

The minimum ambient temperature for non-condensing operation is 0°C.
32
Maximum worst-case ambient temperature (system unit 5APC3100.KBUx-000)
5APC3100.KBU0-000
(C-3965U 2.2 GHz)
5CFAST.xxxx-00
5CFAST.xxxx-10
5AC901.I232-000
5AC901.I485-000
5AC901.ICAN-000
5AC901.ICAN-001
5AC901.IHDA-000
5AC901.IRDY-000
5AC901.IPLK-000
5AC901.ISIO-000
5AC901.IETH-000
5APC3100.KBU1-000
(i3-7100U 2.4 GHz)
60
55
55
55
55
55
55
55
55
55
55
55
55
55
5APC3100.KBU2-000
5APC3100.KBU3-000
(i5-7300U 2.6 GHz)
(i7-7600U 2.8 GHz)
50
Automation PC 3100 User's manual V 2.10
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apc 3100

Table of Contents