Agilent Technologies HP E5574A User Manual page 134

Optical loss analyzer
Table of Contents

Advertisement

command
syntax
description
parameter
response
errors
example
command
syntax
description
parameter
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
HP-IB Programming
OLA Specific Commands
:SENSe:DATA? IL
:SENSe[1|2]:DATA?<wsp>IL
This query returns the Insertion Loss value. It is only applicable to
the applications
• Insertion Loss,
• PDL/Insertion Loss, and
• Coupler Test.
1|2
1
Reads head A
2
Reads head B
Default is 1.
The measured IL value in dB.
The message "Wrong application for this command" is returned, if
the present application is not one of those listed above.
The message "No head connected" is returned, if there is no optical
head attached to the specified channel.
The message "No valid result possible" is returned, if the value
cannot be measured.
OUTPUT 724;":SENS1:DATA? IL"
ENTER 724;A$
:SENSe:DATA? MINMax
:SENSe[1|2]:DATA?<wsp>MINMax
This query returns the MIN/MAX value. It is only applicable to the
MINMax application, which can only be started from the
Powermeter application.
1|2
1
Reads head A
2
Reads head B
Default is 1.
132