Initial Settings And Specifications Of Rs-485 Communication (Pr. 117 To Pr. 120, Pr. 123, Pr. 124, Pr. 549) - Mitsubishi Electric FR-E720-0.1 K Instruction Manual

Table of Contents

Advertisement

Communication operation and setting
4.20.2 Initial settings and specifications of RS-485 communication
(Pr. 117 to Pr. 120, Pr. 123, Pr. 124, Pr. 549)
Used to perform required settings for RS-485 communication between the inverter and personal computer.
Use PU connector of the inverter for communication.
You can perform parameter setting, monitoring, etc. using Mitsubishi inverter protocol or Modbus-RTU protocol.
To make communication between the personal computer and inverter, initialization of the communication
specifications must be made to the inverter.
Data communication cannot be made if the initial settings are not made or there is any setting error.
Parameter
Number
PU communication
117
station number
118
PU communication speed
PU communication stop
119
bit length
PU communication parity
120
check
PU communication
123
waiting time setting
PU communication CR/LF
124
selection
549
Protocol selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 183)
∗1
When "1" (Modbus-RTU protocol) is set in Pr. 549, the setting range within parenthesis is applied.
NOTE
Always reset the inverter after making the initial settings of the parameters. After you have changed the
communication-related parameters, communication cannot be made until the inverter is reset.
206
Initial
Name
Value
0
192
1
2
9999
1
0
Setting Range
Inverter station number specification
0 to 31 (0 to 247)
Set the inverter station numbers when two or more
∗1
inverters are connected to one personal computer.
Communication speed
The setting value X 100 equals the communication
48, 96, 192, 384
speed.
Example)19200bps if 192
Stop bit length
0
1
10
11
0
Without parity check
1
With odd parity check
2
With even parity check
Set the waiting time between data transmission to
0 to 150ms
the inverter and response.
9999
Set with communication data.
0
Without CR/LF
1
With CR
2
With CR/LF
0
Mitsubishi inverter (computer link operation) protocol
1
Modbus-RTU protocol
Description
Data length
1bit
8bit
2bit
1bit
7bit
2bit