Load Cycles And Overload Capabilities - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Technical data of external braking resistor
The external braking resistors are not included in the scope of delivery of the G115D
converter. The following optional external braking resistors are available.
G115D motor-mounted
converter
Frame
size
FSA
FSB
Peak power at 10% cycle time of a 120s cycle.
1)
10.1.5

Load cycles and overload capabilities

Overload capability is the property of the converter to temporarily supply a current that is
higher than the rated current to accelerate a load.
Definitions
Base load
Constant load between the accelerating phases of the converter
HO base load input current
Permissible input current for a "High Overload" load cycle
HO base load output current
Permissible output current for a "High Overload" load cycle
HO base load power
Rated power based on the HO base load output current
If not specified otherwise, the power and current data in the technical data always refer to a
load cycle according to High Overload.
364
Rated power
Resistance
(+/-10%)
210 Ω
0.37 kW to 1.5 kW
240 Ω
480 Ω
160 Ω
2.2 kW to 4 kW
150 Ω
150 Ω
External braking resistor
Continuous
Peak braking
braking power
power
200 W
1200 W
240 W
1440 W
480 W
2880 W
200 W
1200 W
240 W
1440 W
600 W
3600 W
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Article number
1)
6SL3501-1BE32-0AA0
6SL3501-1BE32-4AA0
6SL3501-1BE34-8AA0
6SL3501-1BE32-0BA0
6SL3501-1BE32-4BA0
6SL3501-1BE36-0BA0
SINAMICS G115D distributed drive