Technical Data Of Inputs And Outputs - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

10.1.2

Technical data of inputs and outputs

Property
Fieldbus interface
Operating voltage
24 V power supply
Setpoint resolution
Digital inputs
Configurable DI/DO
Motor temperature
sensor
Fail-safe digital input
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Explanation
PROFINET
AS-i
PROFINET variant:
I/O control variant:
AS-i variant
:
1)
There are three options regarding the 24 V supply:
The converter obtains its 24 V power supply via terminals (glanded variant) or via the M12 L-
code connector or 7/8" connector with 24 V DC ± 15%
The converter obtains its 24 V power supply via X03 (AS-i variant only, M12 A-code, two poles
with AS-i power supply, two poles with 24 V DC ± 15%)
The converter generates its 24 V power supply from the line voltage via the optional 24 V
power supply unit.
0.01 Hz
4 (DI 0 to DI 3)
2 (DIO 24 & DIO 25)
PTC
Pt1000
KTY84
Temperature switch
1 (DI 2 and DI 3)
24 V DC ± 15%
24 V DC ± 15%
26.5 V to 31.6 V, 24 V DC ± 15%
Programmable digital inputs
PNP, SIMATIC-compatible
Unswitched logic supply
Input voltage: High > 11 V, Low < 5 V
Maximum input voltage: 30 V
Maximum input current: 15 mA
Can be configured as digital inputs or outputs
When used as digital inputs:
Switched logic supply
Same specification as DI 0 to DI 3
When used as digital output:
PNP
Switched logic supply
24 V DC/0 A to 0.5A (resistive load)
Continuous current rating: max. 500 mA for two DOs in total
Updating time of all digital outputs: 2 ms
Short-circuit monitoring < 20 Ω
Overtemperature 1650 Ω
Measurement range: -48 °C to 248 °C
Short-circuit monitoring < 603 Ω
Wire-break > 2120 Ω
Measurement range: -48 °C to 248 °C
Short-circuit monitoring < 50 Ω
Wire-break > 2120 Ω
Opened temperature switch ≥ 100 Ω
If you enable safety function STO, then the fail-safe digital input
comprises the two digital inputs DI 2 and DI 3.
The fail-safe digital inputs are in accordance with EN 61131-2:
Input voltage: High > 11 V, Low < 5 V
Maximum input current: 15 mA
Maximum input voltage: 30 V
Response time:
When the debounce time p9651 > 0: Typical 5 ms + p9651,
worst case 15 ms + p9651
When debounce time = 0: Typical 6 ms, worst case 16 ms
Technical data
361

Advertisement

Table of Contents
loading

Table of Contents