Advanced commissioning
6.14 Safe Torque Off (STO) safety function
6.14.2.7

Finalizing online commissioning

Overview
After you finish the configuration of the safety function, proceed through the following
operations to activate the settings.
Precondition
You are online with Startdrive.
Function description
Procedure
1. Press the
2. Confirm the prompt for saving your settings (copy RAM to ROM).
3. Disconnect the online connection.
4. Select the
5. Save the project.
6. Switch off the converter power supply.
7. Wait until all LEDs on the converter go dark (no voltage condition).
8. Switch the converter power supply on again.
Your settings are now active.
226
button to end the safety commissioning.
button to transfer settings from the PG/PC to the converter.
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002