Technical data
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Property
PROFIsafe
Encoder interface
USB interface
Memory card (option-
al)
For AS-i variant, the converter is mainly powered by the specific AS-i power supply through the yellow cable, the supply
1)
voltage range is 26.5 V to 31.6 V. The auxiliary 24 V power supply (24 V DC ±15% ) must be used to run the motor.
10.1.3

Technical data dependent upon the power

Frame size
FSA
FSB
Typical current consumption on 24 V DC power supply
G115D
motor-
mounted
converter
FSA/FSB
The typical current consumption does not include the consumption of connected sensors at
1)
DI 0 to DI 3 from the unswitched 24 V power supply and the consumption of connected sen-
sors/actors at DIO 24/DIO 25 from the switched 24 V power supply.
The typical current consumption does not include the consumption of connected sensors at
2)
DI 0 to DI 3 from the yellow cable and the consumption of connected sensors/actors at DIO
24/DIO 25 from the black cable.
The current consumption for digital inputs DI 0 ~ DI 3 is max. 200 mA in total. The current con-
3)
sumption for digital inputs DI 24 and DI 25 (when DIO 24/DIO 25 is configured as DI) is max.
200 mA in total, and the current consumption for digital outputs DO 24 and DO 25 (when
DIO 24/DIO 25 is configured as DO) is max. 500 mA in total.
362
Explanation
2 (DI 0 & DI 1)
Mini-USB
Slot for SD memory cards
Memory cards (Page 305)
Rated power (kW)
0.37
0.55
0.75
1.1
1.5
2.2
3
4
Typical current consumption from the
24 V power supply, unswtiched
PROFINET variant
290 mA
Yes (for PROFINET version only)
Via 2 digital inputs (DI 0 and DI 1)
HTL, 2-track (A/B)
Power supply: 18 V DC to 30 V DC
Maximum input frequency: 200 kHz
Maximum current consumption: 100 mA
Input current (A)
1.08
1.47
1.79
2.43
3.18
4.65
6.23
8.16
Typical current consumption from the
AS-i cable
1) 3)
I/O variant
Yellow cable
250 mA
90 mA
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Power loss (W)
20.22
24.43
28.52
37.47
49.02
64.35
85.89
114.53
2) 3)
AS-i variant
Black cable
200 mA
SINAMICS G115D distributed drive