General Notes About Maintenance Work - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
11.3.23

General notes about maintenance work

Unintentional starting of the drive unit
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
NOTICE
Improper maintenance
Only authorized qualified personnel may perform the maintenance and servicing. Only
original parts supplied by Siemens AG may be installed.
Only qualified personnel may perform the inspection, maintenance and service work.
Carefully follow the General information gearbox (Page 437).
Table 11- 44 Maintenance measures
Remedy
Monitor and check the geared
motor for unusual noise, vibra-
tions, and changes.
Check the housing temperature.
Check the oil level.
Check the oil level sensor
Check the oil quality.
First oil change after commis-
sioning.
Subsequent oil changes.
Visual inspection of the gear-
box and shaft sealing ring for leaks.
When required, replace the
breather valve.
Clean the gearbox.
Carry out a complete inspection
of the geared motor.
Check the friction clutch and
adjust if necessary.
Check the coupling.
468
WARNING
Interval
Daily; if possible, more frequent-
ly during operation.
After 3 hours, on the first day,
thereafter monthly.
After the first day, and then
every 3000 operating hours, or
at the latest after 6 months.
Regularly and after oil changes.
Every 6 months.
After approximately
10000 operating hours or at the
latest after 2 years.
Every 2 years or
10000 operating hours
.
1)
After the first day, thereafter
monthly.
Once a year.
Depending on degree of soiling,
at least every 6 months.
Every 12 months.
After 500 hours, thereafter once
a year and after every blockage.
For the first time after 3 months. Please refer to the separate
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Description of work
Operation (Page 395)
Checking and changing lubri-
cants (Page 469)
Checking the oil level sensor
(optional) (Page 480)
Checking the oil quality
(Page 472)
Checking and changing lubri-
cants (Page 469)
Checking the gearbox for leaks
(Page 480)
Replacing the vent valve
(Page 480)
Cleaning the geared motor
(Page 395)
Inspecting the geared motor
(Page 395)
Observe the BA 2039 Operating
Instructions.
operating instructions.
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading

Table of Contents