Routine Inspection - EBARA ESA70W Instruction Manual

Multi-stage dry vacuum pump
Table of Contents

Advertisement

(50)

8.2 Routine Inspection

Check periodically that WARNING signal is not output on the LCD controller or
remote output.
No.
Motor Current
2
N2 Gas Flow
3
Vibration / Noise
4
Lubrication oil Quantity
5
Cooling water flow
6
Pumping casing Temp
7
Color of lubrication oil
When the ALARM/WARNING display appears, take action in accordance with
Section 10. "Troubleshooting."
If the lubrication oil amount is lower than the lower limit line of the oil level gauge,
supply the lubrication oil. See the section 8.3 "Lubrication oil" when adding the oil.
WARNING
WARNING
Even when the cause of the ALARM/WARNING signal has been removed the
signal will be maintained until the RESET signal is entered. After you have taken
the remedial action, press the RESET button on the controller or enter the RESET
signal from the control signal connector to reset the WARNING.
Table 8.1 Typical check items
Item
Oil Level Switch and level gauge
Switch off the power supply to the pump first and interrupt the Earth Leakage
Breaker (ELB) and lockout before you start on maintenance.
The pump and exhaust piping will remain at a high temperature during operation
and for a short time after the pump has stopped.
Be sure to avoid contact and keep inflammable substances out of reach.
Do not remove the outer cover during operation.
Sensor
Current Transformer
Flow sensor
-----
Flow sensor
Thermo-Couple
-----
Interval
(recommended)
Every 1 week
Every 1 month
EBARA
Corporation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esa70wn

Table of Contents