Dip Switch - EBARA ESA70W Instruction Manual

Multi-stage dry vacuum pump
Table of Contents

Advertisement

6.4 Dip Switch

Set the dip switches to select the operating modes as shown in Table 6.4/6.5 / 6.6.
No.
1
Data Length
2
Monitor Cooling water and N2
3
Buzzer
4
Operation switched to Remote
5
External start/stop signal
6
7
Dilution N
2
8
BP operation in Remote
* Optional
No.
1
2
3
4
5
6
Remote Interface (IF)
7
8
LCD screen initialize
No.
1
Pump N2 WARNING output
2
3
Back press WARNING output *
4
5
6
7
8
* Optional
Table 6.4 Dip Switch-A Settings
Mode
*
-----
mode
Automatic operation
Table 6.5 Dip Switch-B Settings
Mode
-----
-----
-----
-----
-----
Exclusive special IF
-----
Table 6.6 Dip Switch-C Settings
Mode
-----
-----
-----
-----
-----
-----
Off
7bits
Always
Only during operation
Not used
According to signal
Alternate (Level)
-----
Standard mode
Off
-----
-----
-----
-----
-----
-----
Carry out initialize
Off
Normal Open
-----
Normal Open
-----
-----
-----
-----
-----
(35)
On
8bits
Use
Automatically stop
*
Momentary (Pulse)
-----
Dilution N
-0 mode
2
External signal input
On
-----
-----
-----
-----
-----
No use / standard IF
-----
Do not initialize
On
Normal Close
-----
Normal Close
-----
-----
-----
-----
-----
EBARA
Corporation
Factory
setting
ON
OFF
ON
OFF
OFF
-----
OFF
OFF
Factory
setting
-----
-----
-----
-----
-----
ON
-----
OFF
Factory
setting
OFF
-----
OFF
-----
-----
-----
-----
-----

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esa70wn

Table of Contents