EBARA ESA70W Instruction Manual page 51

Multi-stage dry vacuum pump
Table of Contents

Advertisement

(38)
Characters displayed on LCD screen during dip switch setting
No.
1
Length of communication
2
Monitor condition of
cooling water / Nitrogen
3
4
Remote/Local setting
5
Type of Input signal
6
7
8
BP operation under
REMOTE mode
No.
1
2
3
4
5
6
Remote Interface
7
Phase error monitoring
8
LCD screen initialize
No.
1
PumpN2 Warning output
2
3
Back Pressure Warning
4
5
6
7
8
* Optional
MODE
A1:DATA LENGTH
data
7BIT
A2:WATER&N2
WATCHING ALWAYS
Buzzer
A3:BUZZER
A4:REM. ACTION
CONCORD
*
A5:REM. SIGNAL
ALTERNATE
-----
A6:NO ASSIGNED
N2 0 mode
A7:INACTIVE
A8:BP REM. MODE
AUTO
MODE
-----
B1:NO ASSIGNED
-----
B2:NO ASSIGNED
-----
B3:NO ASSIGNED
-----
B4:NO ASSIGNED
-----
B5:NO ASSIGNED
B6:REMOTEI/O
OPTION
B7:PHASE ERROR
STANDARD
B8:LCD DISPLAY
INITIALIZING
MODE
C1:PUMP N2 WARN
OUTPUT N.OPEN
-----
C2:NO ASSIGNED
C3:BACK PRES.
output
OUTPUT N.OPEN
-----
C4:NO ASSIGNED
-----
C5:NO ASSIGNED
-----
C6:NO ASSIGNED
-----
C7:NO ASSIGNED
-----
C8:NO ASSIGNED
Dip switch A
OFF
INACTIVE
Dip switch B
OFF
Dip switch C
OFF
ON
A1:DATA LENGTH
8BIT
A2:WATER&N2
ONLY RUNNING
A3:BUZZER
ACTIVE
A4:REM. ACTION
STOP
A5:REM. SIGNAL
*
MOMENTARY
A6:NO ASSIGNED
A7:ACTIVE
A8:BP REM. MODE
EXTERNAL INPUT
ON
B1:NO ASSIGNED
B2:NO ASSIGNED
B3:NO ASSIGNED
B4:NO ASSIGNED
B5:NO ASSIGNED
B6:REMOTE I/O
STANDARD
B7:PHASE ERROR
COUNTDOWN ONLY
B8:LCD DISPLAY
UN-INITIALIZING
ON
C1:PUMP N2 WARN
OUTPUT N.CLOSE
C2:NO ASSIGNED
C3:BACK PRES.
OUTPUT N.CLOSE
C4:NO ASSIGNED
C5:NO ASSIGNED
C6:NO ASSIGNED
C7:NO ASSIGNED
C8:NO ASSIGNED
EBARA
Corporation