4.3.2 Power Supply Wiring

Use the correct wiring materials and size to match the operating conditions in
WARNING
accordance with the power consumption rating and ambient air temperature of
the pump.
Be sure to connect the grounding wire.
CAUTION
Wiring should be hard-wired or using twist-lock Hubbel-type connector at power
CAUTION
source side.
Wire the connector for the main power supply. Fig. 4.4 and Tables 4.2 and 4.3
show the connector pin assignment.
Fig 4.4 Power Supply Terminal Block
(As seen from connecting side)
Pump model
Receptacle type
Recep. Manufacturer
Adapted plug type
Suitable wire
* Lengthen grounding wiring 1.2m from other wiring(R,S,T).
A
Table 4.3
Terminal Block Specification
JL04HV-2E22-22PE-B
Japan Aviation Electronics Industry Co., Ltd.
JL04V-6A22-22SE-EB
Table 4.2 Pin Assignment
of Power Supply Terminal Block
Model ESA70W(N)
UL1015 AWG #10
(19)
No. Phase
A
R
B
S
C
T
D
GND