Error Terms
Error Term Inspection

Uncorrected Performance

The following tables show typical performance without error-correction. RF cables are not
used except as noted. Related error terms should be within these values.
Table 11-3 8719ET/ES and 8720ET/ES Uncorrected Port Performance
Parameter and Option
Directivity (ES and ET models)
Source Match (ES Standard)
Source Match (ET Standard)
Source Match (ES Option 400)
Source Match (ES Option 007)
Source Match (ES Option 085)
Load Match (ES Standard)
Load Match (ET Standard)
Load Match (ES Option 400)
Load Match (ES Option 007)
Load Match (ES Option 085)
Reflection Tracking
2
(ES and ET models)
Transmission Tracking
2
1
(ES
and ET
models)
Crosstalk (ES models)
Crosstalk (ET models)
1. Does not include the effect of the cable set on the test ports.
2. Excludes roll-off below 500 MHz, which is typically −18 dB at 100 MHz, and −25 dB at
50 MHz.
3. Measurement Conditions: normalized to a thru, measured with two shorts, 10Hz IF
bandwidth, averaging factor of 8, alternate mode, source power set to the lesser of maximum
power out or the maximum receiver power.
4. Limited by noise floor.
11-8
0.05 to 0.5 GHz
1
24 dB
1
12 dB
1
16 dB
1
20 dB
1
16 dB
1
16 dB
1
22 dB
1
22 dB
20 dB
1
1
26 dB
1
26 dB
±3 dB
±3 dB
3
75 dB
3
101 dB
Frequency Range
0.5 to 2 GHz
27 dB
12 dB
20 dB
20 dB
20 dB
18 dB
20 dB
22 dB
17 dB
24 dB
24 dB
±3 dB
±3 dB
4
95 dB
101 dB
8719ET/20ET/22ET
8719ES/20ES/22ES
RF Network Analyzers
2 to 8 GHz
8 to 20 GHz
21 dB
16 dB
10 dB
8 dB
14 dB
11 dB
11 dB
10 dB
14 dB
11 dB
14 dB
8 dB
12 dB
10 dB
22 dB
17 dB
12 dB
10 dB
15 dB
12 dB
15 dB
10 dB
±3 dB
±3 dB
±3 dB
±3 dB
91 dB
86 dB
101 dB
93 dB