8719ET/20ET/22ET
8719ES/20ES/22ES
RF Network Analyzers
NOTE
Although the performance for all four S-parameters on ES models are
measured, only the uncertainties associated with the items indicated in
2-4
will be used for the system verification. The other characteristics are less
important for verifying system performance and they will not appear on the
printout. If a measurement fails, note which device and S-parameter failed,
and continue on with the remaining tests.
Table 2-4 Supported System Configurations for all ES Models
Verification Device
20 dB attenuator
40 dB attenuator
Airline
Stepped impedance
airline
On the ET models, two S-parameters are measured (S11 and S21). See
Table 2-5
Table 2-5 Supported System Configurations for all ET Models
Verification Device
20 dB attenuator
40 dB attenuator
Airline
Stepped impedance
airline
NOTE
Measured data is displayed as DATA.
Factory data is displayed as MEMORY.
4. When all measurements are complete, the
Disconnect the verification device.
5. Enter Test 28 (using step keys, entry keys, or front panel knob). Repeat steps 1 through
4 in this section with the 40 dB attenuator (Ver Dev 2).
6. Enter Test 29 (using step keys, entry keys, or front panel knob). Repeat steps 1 through
4 in this section with the 50Ω airline (Ver Dev 3). For an example of how to perform
proper airline connections, refer to
Service Guide
S11/S22
S11/S22
Magnitude
Phase
x
x
x
x
x
x
for the uncertainties that are used for system verification.
S11
S11 Phase
Magnitude
x
x
x
x
x
x
Figure 2-12
System Verification and Performance Tests
S21/S12
S21/S12
Magnitude
x
x
x
x
S21
S21 Phase
Magnitude
x
x
x
x
softkey menu will appear.
TESTS
and
Figure
2-13.
System Verification
Table
Phase
x
x
x
x
x
x
x
x
2- 27