New Holland CX720 Repair Manual page 3084

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

BODY AND STRUCTURE - ENVIRONMENT CONTROL Air-conditioning system
Condenser - Remove (E.40.C.32 - F.10.A.10)
1.
Recover refrigerant in accordance with the Refriger-
ant Recovery Procedure in this section.
Open the rotary screen cleaner door (1) to gain ac-
cess to the air conditioning condenser.
2.
Disconnect and cap the refrigerant lines (1) from the
condenser. The fittings are different sizes, labeling
should not be required.
Support the weight of the condenser with blocking or
some other method. Detach the condenser from the
inside mount by removing the three cap screws and
nuts (2).
3.
Detach the condenser from the outside mount by re-
moving the three cap screws and nuts (1) Lift the con-
denser from the combine.
2 4/7/2006
E.40.C / 56
1
10010479
2
10010478
3
10018353

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx740Cx760Cx780Cx820Cx840Cx860 ... Show all

Table of Contents