Idn60..67 Position Switch Point 1..8 - Kollmorgen Sercos II Translation Of The Original Manual

Fieldbus interface for s300 / s700
Table of Contents

Advertisement

®
sercos
IDN Set
3.51

IDN60..67 Position Switch Point 1..8

Each position switch point IDN defines a feedback position that determines the state of a
corresponding position status flag within IDN59 (refer to IDN59).
Data Length: 4 bytes
Data Type:
Minimum:
Maximum:
Default:
Units:
42
04/2016
Signed decimal
0
IDN76, 77, 78, 79, 123
Non-Volatile:
Yes
Write Access:
CP2, CP3, CP4
Run-Up Check:
MDT (60, 61, 62, 63,
Cyclic Transfer:
64, 66)
P1, P2, P3, P4, P5, P6,
ASCII Param.:
P7 and P8
Version:
sercos
Kollmorgen
®
for S300/S700