Modifying the baud rate and optical power

If the baud rate is not set correctly, communication is not possible. The SBAUD #
parameter can be used to set the baud rate, where # is the baud rate.
If the optical power is not set correctly, errors occur in telegram transmission and the red
LED on the amplifier lights up. During normal communication, the green send and receive
LEDs flash, giving the impression that the relevant LED is on. The SLEN # parameter can
be used to specify the optical range for a standard 1 mm² glass fibre cable, where # is the
length of the cable in meters.
Setup software
The parameters can be modified in the setup software, "'SERCOS" screen (ð p.17 /
p.119)
Alternatively, the commands SBAUD # and SLEN # can be entered in the "Terminal"
screen.
®
sercos
for S300/S700
SBAUD
2
2 MBAUD
4
4 MBAUD
8
8 MBAUD
16
16 MBAUD
SLEN
0
Very short connection
1...< 15
Length of the connection with a 1 mm² plastic cable
15...< 30
Length of the connection with a 1 mm² plastic cable
³ 30
Length of the connection with a 1 mm² plastic cable