Configuring A Macro - Extron electronics XMP 240 C AT User Manual

Audio products mixers and processors expansion matrix processor
Hide thumbs Also See for XMP 240 C AT:
Table of Contents

Advertisement

Configuring a Macro

1.
From the
opens.
2.
Select an empty macro slot from the
3.
From the
Local
choosing
NOTE: Macro commands can only be sent to remote destinations via the
LAN 1 port.
a.
After selecting
opens.
b.
Complete the form in the dialog box, including username and password, if required.
c.
Select
d.
Click
e.
Select the newly created remote destination from the
4.
From the
Recall Preset — Recall an existing preset.
Set Group Gain — Set the level of an existing gain group.
Group Gain Inc/Dec — Set the increment/decrement values of an existing gain
group.
Set Group Mute — Mute or unmute an existing mute group.
Gain — Set the gain of a specific gain block on a specific channel.
Mute — Mute or unmute a specific gain block on a specific channel.
Meters On/Off — Enable or disable level meters at the input gain or output
attenuation stages of a specific channel.
SIS Command — Type in a single SIS command to perform an action not listed
above (see
NOTE: Use the
Set Input Format — Specify whether mic/line inputs receive analog signal from the
inputs or digital signal via the Dante network (see
5.
Once the action is chosen, up to four additional selections are made available. These
additional selections must be completed in order to proceed to the next macro step.
For example, if
selection of a gain group to be affected and
the selected group.
6.
When all of the action selections are configured, a new line appears at the bottom of the
form so another action can be configured.
7.
From the
response from each action before executing the next action in the macro or executes
the next command immediately without waiting for an SIS response. The default is
Execute immediately
SIS response syntax (see
a.
Use the
menu, click
Tools
Configure Macros
drop-down, select a destination for the macro action. Choose
Destination
for the local XMP 240 C AT, or
, proceed to step 4.
Local
Add Destination...
to add the device to the drop-down in the
Apply
to close the
Close
Edit Remote Destinations
drop-down, select an action to be configured.
Action
Remote Communication and Control
key in place of
W
is the selected action,
Set Group Gain
drop-down, select whether the XMP 240 C AT waits for an SIS
Next Command
. Responses can be viewed through Extron Dataviewer and follow
DSP SIS Commands
field to enter the amount of delay in seconds. The default is
Delay
. The
Configure Macros
drop-down.
Select Macro
for a remote destination. If
Add Destination...
, the
Edit Remote Destinations
Destinations
dialog box.
Destination
on page 103).
E
and the
(pipe) key in place of
|
in
figure 40
9
Selection 1
determines the gain level of
Selection 2
on page 121).
XMP 240 C AT • Configuration Tools
dialog box
dialog box
column.
drop-down.
}
.
on page 24).
prompts the
0.000
73

Advertisement

Table of Contents
loading

Table of Contents